AS-3001 Exit Sign and Emergency Light Combo, 180 Min Backup

AS-3001 Exit Sign and Emergency Light Combo, 180 Min Backup

库存 / Stock:10000

Nennleistung
3 W (exit sign, mains state)
Notstromdauer
180 min (3 hours)
Schutzart (IP)
IP30
Eingangsspannung
AC 85-265 V, 50/60 Hz
Zertifizierungen
CE, RoHS, LVD
Mindestbestellmenge
100 pcs

AS-3001 Exit Sign and Emergency Light Combo, 180 Min Backup ist AS-3001 exit sign and emergency light combo: 2x3 W heads + 2 W exit sign, 180 min backup, AC 85-265 V, iron and glass housing, 3.7 V Li-ion, 100 lm.

LieferzeitStk
Unter 500 Stk15 Tage
500 – 5000 Stk30 Tage
Über 5000 StkVerhandelbar

Die Lieferzeit wird nach Auftragsbestätigung und Anzahlung berechnet.

Technische Daten

Technische Daten
ModellAS-3001Nennleistung3 W (exit sign, mains state)
Notstromversorgung2 x 3 W LED heads + 2 W exit sign (8 W total)EingangsspannungAC 85-265 V, 50/60 Hz
BatterietypLi-ionNotdauer180 min (3 hours)
LadezeitLess than 15 hoursÜbergabezeitLess than 1 second
IP-SchutzartIP30GehäusematerialIron and glass
EingriffsbeständigkeitsgradIK07 (subject to factory confirmation)MontageWall mounted
Montagebohrabstand190 mmLichtstrom100 lm
LED-Typ2 x 5050 SMD LEDs, 1 per headEnergieeinsparungseffizienzUp to 88%
SchutzfunktionShort-circuit protection, overload protectionAbmessungen (mm)270 x 60 x 190 mm
ZertifizierungCE, RoHS, LVDNettogewicht (kg)0.32 kg
MOQ100 pcsGarantieOther parts 5 years, battery 3 years
Betriebstemperatur0°C to 45°CZykluslebensdauerMore than 500 cycles
Anwendbare NormenCEVerpackungsartNeutral colour box
BatteriechemieLi-ion 3.7 V

Handels- und Logistikdaten

LieferbedingungenEXW
HS-Code9405610000
UrsprungslandChina / Jiangmen
3-Year Battery Warranty · 5-Year Coverage on Other PartsBacked by a registered manufacturer. See full warranty policy →

Beschreibung

html

AS-3001 Exit Sign and Emergency Light Combo - 180 Minutes Backup, Iron and Glass Housing

AS-3001 emergency composite light, blue background main photo with two LED heads and bilingual exit sign panelDe AS-3001 is an exit sign and emergency light combo from Jiangmen Anshine Technology Co., Ltd. – a 2-in-1 combination exit sign that marks the escape route and lights it in one fitting. It is also described as a 2-in-1 exit sign and emergency light or a combined emergency luminaire with exit sign. Two round LED heads sit above a green bilingual EXIT panel with left and right arrows and a running-man pictogram, all in an iron and glass housing measuring 270 x 60 x 190 mm (27 x 6 x 19 cm). The fitting carries a 3 W EXIT sign in normal mains state and delivers 2 x 3 W LED heads plus a 2 W exit sign (8 W total) in emergency mode. It uses 2 x 5050 SMD LEDs (1 per head) and delivers 100 lm. Mains input is AC 85-265 V at 50/60 Hz, and a 3.7 V Li-ion battery provides 180 minutes (3 hours) of emergency lighting. The fitting is wall mounted, with 190 mm between the fixing centres.

At a glance

  • Model: AS-3001, exit sign and emergency light combo, iron and glass housing
  • Emergency runtime: 180 min (3 hours)
  • Normal power: 3 W EXIT sign; emergency output: 2 x 3 W LED heads + 2 W exit sign, 8 W total
  • Light source: 2 x 5050 SMD LEDs, 1 per head, 100 lm
  • Input voltage: AC 85-265 V, 50/60 Hz, covering 120 V and 230 V markets
  • Battery: Li-ion 3.7 V; full charge in less than 15 hours; transfer in less than 1 second
  • Housing size: 270 x 60 x 190 mm (27 x 6 x 19 cm), built-in carry handle
  • Net weight: 0.32 kg; mounting hole spacing 190 mm
  • Installation: wall mounted (190 mm fixing centres)
  • Energy saving: up to 88% (as stated on the product catalogue)
  • Protection: short-circuit protection and overload protection
  • Packing: neutral colour box
  • Operating temperature: 0°C to 45°C; battery cycle life more than 500 cycles
  • Certifications: CE, RoHS and LVD as shown on the product catalogue
  • IP rating: IP30, for dry indoor locations
  • Warranty: 5 years on other parts, 3 years on the battery; battery capacity confirmed with the quotation

180 minutes of emergency lighting and escape route marking

The AS-3001 provides 180 minutes (3 hours) of emergency lighting at rated load from its 3.7 V Li-ion battery. On mains power it draws about 3 W for the EXIT sign from an AC 85-265 V, 50/60 Hz supply, so one unit covers both 120 V and 230 V installations without a transformer. When mains fails, the two LED heads and the EXIT panel switch to battery power - 2 x 3 W heads plus a 2 W sign, 8 W in total - with transfer in less than 1 second and a full charge in less than 15 hours. The LED heads use 5050 SMD LEDs, one per head, for a total output of 100 lm. The product catalogue states energy saving of up to 88%.

Iron and glass housing, twin heads and EXIT panel in one fitting

Exploded view of AS-3001 exit sign and emergency light components: housing, LED heads, PCB, exit legend panel and accessoriesThe body combines an iron frame with a glass panel and measures 270 x 60 x 190 mm (27 x 6 x 19 cm); a carry handle makes it easy to position. The net weight is 0.32 kg, and the fitting is wall mounted with 190 mm mounting hole spacing between the fixing centres. Two round LED heads sit above the bilingual EXIT panel, giving both route marking and area lighting from a single point, which saves fixing positions and simplifies installation. The unit is rated IP30 and intended for dry indoor locations; it is not specified for humid, wet, dusty or outdoor positions. It ships in a neutral colour box; operating temperature is 0°C to 45°C, the battery is rated for more than 500 cycles, and short-circuit and overload protection are built in. The impact rating is IK07, subject to factory confirmation for this housing.

Exit routes, backup power and fire compliance

The AS-3001 suits exit routes, stairwells, hotel corridors, offices and indoor retail areas where an exit sign and emergency light are needed together. As a wall mounted fitting it is fixed above doorways and along escape routes at 190 mm fixing centres. It is a battery backup fitting: the rechargeable Li-ion battery supplies backup power during a blackout, so both the EXIT panel and the LED heads stay on when mains power fails. For building fire safety, the unit is intended to support fire compliance and building fire code requirements for emergency lighting and life safety; always confirm local fire regulations and the installation code for your market with the project engineer before specifying the product.

Documentation and order terms

Buyers sourcing an exit sign and emergency light combo typically search by product type, battery backup performance, installation scenario and documentation. The AS-3001 is a 2-in-1 combination exit sign with a 3.7 V Li-ion battery, 2 x 5050 SMD LEDs and 180 minutes of emergency duration. CE, RoHS and LVD are the certifications shown for this product. No EN or IEC standard number is claimed on this page; certificate numbers and test reports for this model are confirmed on request. For a specific market-access requirement we provide the technical documentation required to apply for that certificate.

Order, packaging and commercial terms

  • MOQ: 100 pcs; OEM and ODM specifications welcome
  • Trade terms: EXW Jiangmen; origin: China / Jiangmen
  • HS code: 9405610000
  • Stock: 10,000 pcs
  • Packing: neutral colour box
  • Lead time: 15 days under 500 pcs, 30 days for 500-5,000 pcs, to be negotiated above 5,000 pcs
  • Certifications: CE, RoHS and LVD; certificate numbers and reports on request

Specifications are subject to change without notice. Source: AS-3001 product parameter sheet and product catalogue supplied by the customer, Jiangmen Anshine Technology Co., Ltd.

Batterie & Transportvorschriften

Jedes Produkt mit Lithiumzelle gilt als Gefahrgut. Dies sind die Felder, die ein Spediteur abfragt.

ChemieLi-ion 3.7 V
UN38.3-PrüfberichtAuf Anfrage
SDS / MSDSAuf Anfrage

Notbeleuchtung nach EN 1838

EN 1838:2013 legt in der EU die Mindestanforderungen an die Beleuchtung in Notfällen fest und unterscheidet drei Funktionen: ① Fluchtwegbeleuchtung — mindestens 1 lx im Mittel entlang des Fluchtwegs, Verhältnis max/min ≤ 10:1; ② Beleuchtung offener Bereiche (Anti-Panik) — mindestens 0,5 lx; ③ Beleuchtung von Arbeitsbereichen mit hohem Risiko — mindestens 10 % der Normalbeleuchtung und nicht unter 15 lx. Unsere Notleuchten sind auf diese Werte ausgelegt. Die erforderliche Notbetriebsdauer (üblich 1 h oder 3 h) und die für Ihr Projekt nötige Zertifizierung werden je Modell und Auftrag bestätigt — fordern Sie Konformitätserklärung bzw. Prüfbericht für das gewünschte Modell an.

Fragen zu diesem Produkt

Wie lange bleiben das Kombigerät aus Rettungszeichenleuchte und Notleuchte AS-3001 bei einem Stromausfall beleuchtet?
180 Minuten (3 Stunden) Notbeleuchtung bei Nennlast. Das AS-3001 ist ein 2-in-1-Kombigerät aus Rettungszeichenleuchte mit zwei 3-W-LED-Köpfen und einem 2-W-EXIT-Panel, das von einer 3,7-V-Li-ion-Batterie gespeist wird. Die Umschaltung in den Notbetrieb dauert weniger als 1 Sekunde, und eine vollständige Ladung dauert weniger als 15 Stunden. Sowohl das EXIT-Zeichen als auch die LED-Köpfe bleiben während eines Stromausfalls eingeschaltet und markieren den Fluchtweg und beleuchten den Korridor für die vollen 180 Minuten.
Welche Eingangsspannung akzeptiert das Kombigerät aus Rettungszeichenleuchte und Notleuchte AS-3001?
AC 85-265 V bei 50/60 Hz. Eine Einheit deckt daher sowohl 120-V- als auch 230-V-Installationen ohne Transformator oder Konverter ab, sodass dieselbe Leuchte in mehreren Märkten spezifiziert werden kann. Bitte geben Sie bei der Angebotsanfrage die Netzspannung Ihres Marktes an, damit wir die Versorgungskonfiguration und die Batterieladeanordnung für diesen Markt bestätigen können.
Wie hoch sind Lichtleistung und Leistungsaufnahme des Kombigeräts AS-3001?
Das AS-3001 verwendet zwei 5050-SMD-LEDs, eine pro Kopf, mit einer Gesamtlichtleistung von 100 lm. Im normalen Netzbetrieb nimmt das EXIT-Zeichen etwa 3 W auf; im Notbetrieb laufen die beiden 3-W-LED-Köpfe und das 2-W-EXIT-Panel mit 2 x 3 W + 2 W (insgesamt 8 W). Der Produktkatalog gibt eine Energieeinsparung von bis zu 88 % an. Dieses Twin-Head-Design beleuchtet Korridore und Treppenhäuser, während das grüne zweisprachige EXIT-Panel den Fluchtweg markiert und zwei Funktionen in einer Leuchte vereint.
Aus welchem Material besteht das AS-3001 und welche Größe hat es?
Das AS-3001 ist ein wandmontiertes Kombigerät aus Rettungszeichenleuchte und Notleuchte mit einem Gehäuse aus Eisen und Glas mit den Maßen 270 x 60 x 190 mm (27 x 6 x 19 cm) und einem integrierten Tragegriff. Es wiegt 0,32 kg, und der Befestigungslochabstand von 190 mm gibt die Befestigungsmitten für die Wandmontage an. Es wird in einer neutralen Farbbox geliefert. Es ist für trockene Innenbereiche wie Korridore, Treppenhäuser, Büros, Hotels und Innenverkaufsflächen vorgesehen, nicht für feuchte, nasse, staubige oder Außenbereiche. Das Gehäuse ist für den trockenen Innengebrauch mit IP30 bewertet, mit Kurzschluss- und Überlastschutz; die Kartonverpackungsdaten werden mit dem Angebot bestätigt, bitte fordern Sie das Datenblatt an, wenn Sie diese Angaben benötigen.
Über welche Zertifizierungen verfügt das AS-3001?
CE, RoHS und LVD sind die Zertifizierungen, die für dieses Produkt im Produktkatalog angegeben sind. Für dieses Modell werden keine weiteren Marktzugangszertifikate oder -listungen beansprucht, und auf dieser Seite wird keine EN- oder IEC-Normnummer beansprucht. Zertifikatsnummern und Prüfberichte werden auf Anfrage bestätigt; für eine bestimmte Marktzugangsanforderung stellen wir die technische Dokumentation bereit, die für die Beantragung dieses Zertifikats erforderlich ist.
Wie hoch sind Mindestbestellmenge und Lieferzeit für das AS-3001?
Die Mindestbestellmenge beträgt 100 Stück, Handelsbedingungen EXW Jiangmen, Herkunft China / Jiangmen, HS-Code 9405610000. Die Lieferzeit beträgt 15 Tage bei unter 500 Stück, 30 Tage für 500-5.000 Stück und ist über 5.000 Stück zu verhandeln. Der Lagerbestand beträgt 10.000 Stück, und die Verpackung ist eine neutrale Farbbox. OEM- und ODM-Spezifikationen sind willkommen. Die Garantie beträgt 5 Jahre auf andere Teile und 3 Jahre auf die Batterie; die Batteriekapazität wird mit dem Angebot bestätigt.

Fragen Sie zu AS-3001 Exit Sign and Emergency Light Combo, 180 Min Backup

Geben Sie Menge und Zielort an, und wir antworten mit einer Spezifikation und einem Angebot.