AS-3001 Exit Sign and Emergency Light Combo, 180 Min Backup

AS-3001 Exit Sign and Emergency Light Combo, 180 Min Backup

库存 / Stock:10000

Rated Power
3 W (exit sign, mains state)
Emergency Duration
180 min (3 hours)
IP Rating
IP30
Input Voltage
AC 85-265 V, 50/60 Hz
Certifications
CE, RoHS, LVD
Minimum Order Quantity
100 pcs

AS-3001 Exit Sign and Emergency Light Combo, 180 Min Backup is AS-3001 exit sign and emergency light combo: 2x3 W heads + 2 W exit sign, 180 min backup, AC 85-265 V, iron and glass housing, 3.7 V Li-ion, 100 lm.

Lead Timepcs
Under 500 pcs15 days
500 – 5000 pcs30 days
Over 5000 pcsNegotiable

Delivery time is counted after order confirmation and deposit.

Technical Specifications

Technical Specifications
ModelAS-3001Rated Power3 W (exit sign, mains state)
Emergency Power2 x 3 W LED heads + 2 W exit sign (8 W total)Input VoltageAC 85-265 V, 50/60 Hz
Battery TypeLi-ionEmergency Duration180 min (3 hours)
Charging TimeLess than 15 hoursTransfer TimeLess than 1 second
IP RatingIP30Housing MaterialIron and glass
Impact Resistance GradeIK07 (subject to factory confirmation)MountingWall mounted
Mounting Hole Spacing190 mmLuminous flux100 lm
LED Type2 x 5050 SMD LEDs, 1 per headEnergy Saving EfficiencyUp to 88%
Protection FunctionShort-circuit protection, overload protectionDimensions (mm)270 x 60 x 190 mm
CertificationCE, RoHS, LVDNet Weight (kg)0.32 kg
MOQ100 pcsWarrantyOther parts 5 years, battery 3 years
Operating Temperature0°C to 45°CCycle LifeMore than 500 cycles
Applicable StandardsCEPacking TypeNeutral colour box
Battery ChemistryLi-ion 3.7 V

Trade & Logistics Specifications

Trade TermsEXW
HS Code9405610000
Country of OriginChina / Jiangmen
3-Year Battery Warranty · 5-Year Coverage on Other PartsBacked by a registered manufacturer. See full warranty policy →

Description

html

AS-3001 Exit Sign and Emergency Light Combo - 180 Minutes Backup, Iron and Glass Housing

AS-3001 emergency composite light, blue background main photo with two LED heads and bilingual exit sign panelThe AS-3001 is an exit sign and emergency light combo from Jiangmen Anshine Technology Co., Ltd. - a 2-in-1 combination exit sign that marks the escape route and lights it in one fitting. It is also described as a 2-in-1 exit sign and emergency light or a combined emergency luminaire with exit sign. Two round LED heads sit above a green bilingual EXIT panel with left and right arrows and a running-man pictogram, all in an iron and glass housing measuring 270 x 60 x 190 mm (27 x 6 x 19 cm). The fitting carries a 3 W EXIT sign in normal mains state and delivers 2 x 3 W LED heads plus a 2 W exit sign (8 W total) in emergency mode. It uses 2 x 5050 SMD LEDs (1 per head) and delivers 100 lm. Mains input is AC 85-265 V at 50/60 Hz, and a 3.7 V Li-ion battery provides 180 minutes (3 hours) of emergency lighting. The fitting is wall mounted, with 190 mm between the fixing centres.

At a glance

  • Model: AS-3001, exit sign and emergency light combo, iron and glass housing
  • Emergency runtime: 180 min (3 hours)
  • Normal power: 3 W EXIT sign; emergency output: 2 x 3 W LED heads + 2 W exit sign, 8 W total
  • Light source: 2 x 5050 SMD LEDs, 1 per head, 100 lm
  • Input voltage: AC 85-265 V, 50/60 Hz, covering 120 V and 230 V markets
  • Battery: Li-ion 3.7 V; full charge in less than 15 hours; transfer in less than 1 second
  • Housing size: 270 x 60 x 190 mm (27 x 6 x 19 cm), built-in carry handle
  • Net weight: 0.32 kg; mounting hole spacing 190 mm
  • Installation: wall mounted (190 mm fixing centres)
  • Energy saving: up to 88% (as stated on the product catalogue)
  • Protection: short-circuit protection and overload protection
  • Packing: neutral colour box
  • Operating temperature: 0°C to 45°C; battery cycle life more than 500 cycles
  • Certifications: CE, RoHS and LVD as shown on the product catalogue
  • IP rating: IP30, for dry indoor locations
  • Warranty: 5 years on other parts, 3 years on the battery; battery capacity confirmed with the quotation

180 minutes of emergency lighting and escape route marking

The AS-3001 provides 180 minutes (3 hours) of emergency lighting at rated load from its 3.7 V Li-ion battery. On mains power it draws about 3 W for the EXIT sign from an AC 85-265 V, 50/60 Hz supply, so one unit covers both 120 V and 230 V installations without a transformer. When mains fails, the two LED heads and the EXIT panel switch to battery power - 2 x 3 W heads plus a 2 W sign, 8 W in total - with transfer in less than 1 second and a full charge in less than 15 hours. The LED heads use 5050 SMD LEDs, one per head, for a total output of 100 lm. The product catalogue states energy saving of up to 88%.

Iron and glass housing, twin heads and EXIT panel in one fitting

Exploded view of AS-3001 exit sign and emergency light components: housing, LED heads, PCB, exit legend panel and accessoriesThe body combines an iron frame with a glass panel and measures 270 x 60 x 190 mm (27 x 6 x 19 cm); a carry handle makes it easy to position. The net weight is 0.32 kg, and the fitting is wall mounted with 190 mm mounting hole spacing between the fixing centres. Two round LED heads sit above the bilingual EXIT panel, giving both route marking and area lighting from a single point, which saves fixing positions and simplifies installation. The unit is rated IP30 and intended for dry indoor locations; it is not specified for humid, wet, dusty or outdoor positions. It ships in a neutral colour box; operating temperature is 0°C to 45°C, the battery is rated for more than 500 cycles, and short-circuit and overload protection are built in. The impact rating is IK07, subject to factory confirmation for this housing.

Exit routes, backup power and fire compliance

The AS-3001 suits exit routes, stairwells, hotel corridors, offices and indoor retail areas where an exit sign and emergency light are needed together. As a wall mounted fitting it is fixed above doorways and along escape routes at 190 mm fixing centres. It is a battery backup fitting: the rechargeable Li-ion battery supplies backup power during a blackout, so both the EXIT panel and the LED heads stay on when mains power fails. For building fire safety, the unit is intended to support fire compliance and building fire code requirements for emergency lighting and life safety; always confirm local fire regulations and the installation code for your market with the project engineer before specifying the product.

Documentation and order terms

Buyers sourcing an exit sign and emergency light combo typically search by product type, battery backup performance, installation scenario and documentation. The AS-3001 is a 2-in-1 combination exit sign with a 3.7 V Li-ion battery, 2 x 5050 SMD LEDs and 180 minutes of emergency duration. CE, RoHS and LVD are the certifications shown for this product. No EN or IEC standard number is claimed on this page; certificate numbers and test reports for this model are confirmed on request. For a specific market-access requirement we provide the technical documentation required to apply for that certificate.

Order, packaging and commercial terms

  • MOQ: 100 pcs; OEM and ODM specifications welcome
  • Trade terms: EXW Jiangmen; origin: China / Jiangmen
  • HS code: 9405610000
  • Stock: 10,000 pcs
  • Packing: neutral colour box
  • Lead time: 15 days under 500 pcs, 30 days for 500-5,000 pcs, to be negotiated above 5,000 pcs
  • Certifications: CE, RoHS and LVD; certificate numbers and reports on request

Specifications are subject to change without notice. Source: AS-3001 product parameter sheet and product catalogue supplied by the customer, Jiangmen Anshine Technology Co., Ltd.

Battery & Transport Compliance

Any product containing a lithium cell ships as dangerous goods. These are the fields a freight forwarder will ask for.

ChemistryLi-ion 3.7 V
UN38.3 test summaryAvailable on request
SDS / MSDSAvailable on request

Emergency Lighting Compliance — EN 1838

EN 1838:2013 (Lighting applications — Emergency lighting) defines the minimum lighting requirements for emergency situations within the EU. It covers three functions: ① Escape-route lighting — minimum average 1 lx along the escape path, max-to-min ratio ≤ 10:1; ② Open-area (anti-panic) lighting — minimum average 0.5 lx across the area; ③ High-risk task-area lighting — at least 10% of normal illumination and not less than 15 lx. Our emergency luminaires are designed to meet these illumination levels. The applicable duration (typically 1 h or 3 h) and the notified-body certification for your project are confirmed per model and order — request the declaration of conformity / test report for the exact model you specify.

Questions About This Product

How long does the AS-3001 exit sign and emergency light combo stay lit during a power failure?
180 minutes (3 hours) of emergency lighting at rated load. The AS-3001 is a 2-in-1 combination exit sign with twin 3 W LED heads and a 2 W EXIT panel, running from a 3.7 V Li-ion battery. Transfer to emergency mode takes less than 1 second and a full charge takes less than 15 hours. Both the EXIT sign and the LED heads stay on during a blackout, marking the escape route and lighting the corridor for the full 180 minutes.
What input voltage does the AS-3001 exit sign and emergency light combo accept?
AC 85-265 V at 50/60 Hz. One unit therefore covers both 120 V and 230 V installations without a transformer or converter, so the same fitting can be specified across several markets. Please state your market voltage when requesting a quotation so that we can confirm the supply configuration and the battery charging arrangement for that market.
What are the light output and power of the AS-3001 combo?
The AS-3001 uses two 5050 SMD LEDs, one per head, giving a total light output of 100 lm. In normal mains state the EXIT sign draws about 3 W; in emergency mode the two 3 W LED heads and the 2 W EXIT panel run at 2 x 3 W + 2 W (8 W total). The product catalogue states energy saving of up to 88%. This twin-head design lights corridors and stairwells while the green bilingual EXIT panel marks the escape route, combining two functions in one fitting.
What is the AS-3001 made of and what size is it?
The AS-3001 is a wall mounted exit sign and emergency light combo with an iron and glass housing measuring 270 x 60 x 190 mm (27 x 6 x 19 cm) and a built-in carry handle. It weighs 0.32 kg, and the 190 mm mounting hole spacing gives the fixing centres for wall installation. It ships in a neutral colour box. It is intended for dry indoor locations such as corridors, stairwells, offices, hotels and indoor retail areas, not for humid, wet, dusty or outdoor positions. The enclosure is rated IP30 for dry indoor use, with short-circuit and overload protection; carton packing data is confirmed with the quotation, so please ask for the datasheet if you need those figures.
What certifications does the AS-3001 carry?
CE, RoHS and LVD are the certifications shown for this product on the product catalogue. No other market-access certificates or listings are claimed for this model, and no EN or IEC standard number is claimed on this page. Certificate numbers and test reports are confirmed on request; for a specific market-access requirement, we provide the technical documentation required to apply for that certificate.
What is the minimum order quantity and lead time for the AS-3001?
MOQ is 100 pcs, trade terms EXW Jiangmen, origin China / Jiangmen, HS code 9405610000. Lead time is 15 days under 500 pcs, 30 days for 500-5,000 pcs and to be negotiated above 5,000 pcs. Stock is 10,000 pcs and packing is a neutral colour box. OEM and ODM specifications are welcome. Warranty is 5 years on other parts and 3 years on the battery; battery capacity is confirmed with the quotation.

Ask about AS-3001 Exit Sign and Emergency Light Combo, 180 Min Backup