AS-3003 Exit Sign and Emergency Light Combo, 180-Minute Backup
库存 / Stock:10000
- Rated Power
- 5 W EXIT panel + 2 × 5 W + 3 W emergency heads (13 W total)
- Emergency Duration
- 180 min
- IP Rating
- IP30
- Input Voltage
- AC 85-265 V, 50/60 Hz
- Certifications
- CE, RoHS
- Minimum Order Quantity
- 100 pcs
AS-3003 Exit Sign and Emergency Light Combo, 180-Minute Backup is AS-3003 Exit Sign and Emergency Light Combo: 5 W panel, 2x5 W + 3 W (13 W) output, AC 85-265 V, IP30, 3.7 V 2000 mAh Li-ion, 180 min backup.
Delivery time is counted after order confirmation and deposit.
Technical Specifications
| Model | AS-3003 | Rated Power | 5 W EXIT panel + 2 × 5 W + 3 W emergency heads (13 W total) |
|---|---|---|---|
| Input Voltage | AC 85-265 V, 50/60 Hz | Battery Type | Li-ion 3.7 V |
| Battery Capacity | 2000 mAh | Battery Energy (Wh) | 7.4 Wh |
| Emergency Duration | 180 min | Charging Time | Less than 15 hours |
| Transfer Time | Less than 1 second | IP Rating | IP30 |
| Housing Material | ABS | Impact Resistance Grade | IK07 |
| Mounting | Wall-mounted | Luminous Flux | Confirmed with engineering |
| Dimensions (mm) | 465 × 52 × 200 mm | Net Weight (kg) | 1.005 kg |
| Certification | CE, RoHS | Warranty | 5 years (battery 3 years) |
| MOQ | 100 pcs | Operating Temperature | 0°C to 50°C |
| Cycle Life | More than 500 cycles | Applicable Standards | CE |
| Packing Size (cm) | 56 × 48 × 44 cm | Package Net Weight (kg) | 10.05 kg |
| Package Gross Weight (kg) | 12.45 kg | Battery Chemistry | Li-ion |
Trade & Logistics Specifications
| Trade Terms | EXW |
|---|---|
| Package Size | 56 × 48 × 44 cm |
| Gross Weight | 12.45 kg per carton (10 pcs/carton) |
| HS Code | 9405610000 |
| Country of Origin | China / Jiangmen |
Description
AS-3003 Exit Sign and Emergency Light Combo — 180-Minute Backup, IP30 ABS Housing
The AS-3003 is an exit sign and emergency light combo from Jiangmen Anshine Technology Co., Ltd. — a 2-in-1 exit sign and emergency light that marks the escape route and lights it in one fitting. It is also described as a combination exit sign or a combined emergency luminaire with exit sign. It measures 465 × 52 × 200 mm, uses an ABS housing, and runs from a 3.7 V 2000 mAh Li-ion battery (7.4 Wh). Mains input is AC 85–265 V at 50/60 Hz. The exit panel is rated 5 W and the emergency output is 2 × 5 W + 3 W (13 W in total). In emergency mode the unit delivers 180 minutes of illumination at rated load. Rated IP30, it is intended for dry indoor locations. The exit legend is available in green or red.
The EXIT panel sits between two side-mounted LED heads, so one fitting marks the escape route and lights it at the same time. The internal ledger specifies 2835 SMD LEDs, 12 pieces, in the heads. Charging time is less than 15 hours and the unit operates at 0°C to 50°C. Transfer time is less than 1 second.
At a Glance — Why Buyers Choose the AS-3003
- Exit sign and emergency light combo: 2-in-1 fitting with a 5 W exit panel plus 2 × 5 W + 3 W (13 W) emergency output.
- 180 minutes of backup: 3.7 V 2000 mAh Li-ion battery (7.4 Wh), 180 minutes at rated load.
- Wide-range mains input: AC 85–265 V, 50/60 Hz, covering 120 V and 230 V supplies.
- 12 × 2835 SMD LEDs: head specification from the internal product ledger.
- IP30 indoor rating: ABS housing, 465 × 52 × 200 mm, 1.005 kg net weight, 0°C to 50°C operation.
- Recharge and legend options: charging time less than 15 hours; green or red legend, 10 pcs per carton; OEM and ODM enquiries welcome.
180 Minutes of Emergency Operation
The AS-3003 switches to its 3.7 V 2000 mAh Li-ion battery (7.4 Wh) automatically when the mains supply fails and provides 180 minutes of emergency illumination at rated load. Emergency output is 2 × 5 W + 3 W, 13 W in total. Charging time is less than 15 hours; transfer time is less than 1 second. The battery is covered for 3 years and the rest of the fixture for 5 years.
Exit Panel and Side LED Heads
The 465 × 52 × 200 mm fitting combines a central EXIT panel with two square LED heads mounted on either side. The exit legend is supplied in green or red. The internal ledger specifies 2835 SMD LEDs, 12 pieces, in the heads; the exit panel is rated 5 W. Luminous flux, colour temperature and colour rendering index are not stated on the current catalogue page and are confirmed with our engineering team for your project.
ABS Housing and IP30 Indoor Rating
The body is made of ABS and weighs 1.005 kg net. With an IP30 rating it is intended for dry, indoor environments such as corridors, stairwells, offices and indoor retail areas. It is not intended for humid, dusty, wet or outdoor locations. Operating temperature is 0°C to 50°C; impact resistance (IK) and ingress protection above IP30 are not stated on the current catalogue page.
Built-In Protection and Energy Efficiency
The catalogue records a high-capacity Li-ion battery, all-gold shell construction, energy saving efficiency of up to 88%, short-circuit protection, lightning protection and overload protection. The battery is rated for more than 500 charge and discharge cycles. Charging time is less than 15 hours; detailed charging parameters — charge current and charge voltage — are not published for this model and are confirmed on request.
Wide-Range AC Input
AC 85–265 V, 50/60 Hz input covers low- and high-voltage mains across Europe, the Middle East, South-East Asia, Africa and South America, so distributors can stock one SKU for multiple markets. The same unit operates on 120 V and 230 V supplies without a transformer or converter.
Made to Match Your Brand and Project
OEM and ODM orders are welcome at an MOQ of 100 pcs. Please send your target quantity, destination port and any branding, artwork or packaging requirements so our team can confirm the available options and provide a formal quotation. The catalogue lists an all-gold shell and the ledger lists a neutral colour box; custom colours and non-standard configurations are subject to engineering confirmation.
Where It Works
Suitable for dry indoor interiors: corridors, stairwells, offices, schools, hotels, shopping centres, warehouses and plant rooms. The AS-3003 carries an IP30 rating and is intended for indoor, dry locations only — not for humid, dusty, wet or outdoor environments. The fitting is wall-mounted; fixing accessories can be confirmed with our sales team for your specific installation.
Emergency Lighting Standards and Documentation
Buyers sourcing an exit sign and emergency light combo typically search by product type, battery backup performance, installation scenario and documentation. The AS-3003 is a 2-in-1 combination exit sign with a 3.7 V 2000 mAh Li-ion battery, 12 × 2835 SMD LEDs and 180 minutes of emergency duration. CE and RoHS marks appear on the AS-3003 catalogue page. CE is the applicable standard marked for this model; no EN or IEC standard number is published on the catalogue page, so none is claimed here. Certificate numbers and test reports are confirmed on request.
Order, Packaging and Commercial Terms
Send us your quantity and destination port, and we will confirm the commercial details with the quotation.
- MOQ: 100 pcs
- Stock: 10000
- Lead time: Under 500 pcs: 15 days; 500–5,000 pcs: 30 days; above 5,000 pcs: to be negotiated
- Payment: To be confirmed at quotation
- HS code: 9405610000
- Trade terms: EXW Jiangmen
- Country of origin: China / Jiangmen
- Packing: 10 pcs per carton, 56 × 48 × 44 cm, 12.45 kg gross weight; 1.005 kg net per unit
- Warranty: 5 years (battery 3 years)
- Customisation: OEM and ODM enquiries welcome
Request a Quote or Samples
Tell us your target quantity and destination port — we will reply within one working day with a quotation, the full specification sheet and sample arrangements. For project tenders, include the intended installation environment and any certification documents you require.
Specifications are subject to change without notice. Source: AS-3003 Product Catalogue and internal product ledger, Jiangmen Anshine Technology Co., Ltd.
Battery & Transport Compliance
Any product containing a lithium cell ships as dangerous goods. These are the fields a freight forwarder will ask for.
| Chemistry | Li-ion |
|---|---|
| UN38.3 test summary | Available on request |
| SDS / MSDS | Available on request |
Emergency Lighting Compliance — EN 1838
Questions About This Product
How long does the AS-3003 exit sign and emergency light combo stay lit during a power failure?
What input voltage does the AS-3003 combination exit sign accept?
What battery does the AS-3003 use, and how long does it take to recharge?
Can the AS-3003 be installed outdoors or in damp locations?
What certifications does the AS-3003 carry?
What is the minimum order quantity and lead time for the AS-3003?
Ask about AS-3003 Exit Sign and Emergency Light Combo, 180-Minute Backup
Include quantity and destination and we reply with a specification and quotation.