AS-3003 Exit Sign and Emergency Light Combo, 180-Minute Backup

AS-3003 Exit Sign and Emergency Light Combo, 180-Minute Backup

库存 / Stock:10000

Rated Power
5 W EXIT panel + 2 × 5 W + 3 W emergency heads (13 W total)
Emergency Duration
180 min
IP Rating
IP30
Input Voltage
AC 85-265 V, 50/60 Hz
Certifications
CE, RoHS
Minimum Order Quantity
100 pcs

AS-3003 Exit Sign and Emergency Light Combo, 180-Minute Backup is AS-3003 Exit Sign and Emergency Light Combo: 5 W panel, 2x5 W + 3 W (13 W) output, AC 85-265 V, IP30, 3.7 V 2000 mAh Li-ion, 180 min backup.

Lead Timepcs
Under 500 pcs15 days
500 – 5000 pcs30 days
Over 5000 pcsNegotiable

Delivery time is counted after order confirmation and deposit.

Technical Specifications

Technical Specifications
ModelAS-3003Rated Power5 W EXIT panel + 2 × 5 W + 3 W emergency heads (13 W total)
Input VoltageAC 85-265 V, 50/60 HzBattery TypeLi-ion 3.7 V
Battery Capacity2000 mAhBattery Energy (Wh)7.4 Wh
Emergency Duration180 minCharging TimeLess than 15 hours
Transfer TimeLess than 1 secondIP RatingIP30
Housing MaterialABSImpact Resistance GradeIK07
MountingWall-mountedLuminous FluxConfirmed with engineering
Dimensions (mm)465 × 52 × 200 mmNet Weight (kg)1.005 kg
CertificationCE, RoHSWarranty5 years (battery 3 years)
MOQ100 pcsOperating Temperature0°C to 50°C
Cycle LifeMore than 500 cyclesApplicable StandardsCE
Packing Size (cm)56 × 48 × 44 cmPackage Net Weight (kg)10.05 kg
Package Gross Weight (kg)12.45 kgBattery ChemistryLi-ion

Trade & Logistics Specifications

Trade TermsEXW
Package Size56 × 48 × 44 cm
Gross Weight12.45 kg per carton (10 pcs/carton)
HS Code9405610000
Country of OriginChina / Jiangmen
3-Year Battery Warranty · 5-Year Coverage on Other PartsBacked by a registered manufacturer. See full warranty policy →

Description

AS-3003 Exit Sign and Emergency Light Combo — 180-Minute Backup, IP30 ABS Housing

The AS-3003 is an exit sign and emergency light combo from Jiangmen Anshine Technology Co., Ltd. — a 2-in-1 exit sign and emergency light that marks the escape route and lights it in one fitting. It is also described as a combination exit sign or a combined emergency luminaire with exit sign. It measures 465 × 52 × 200 mm, uses an ABS housing, and runs from a 3.7 V 2000 mAh Li-ion battery (7.4 Wh). Mains input is AC 85–265 V at 50/60 Hz. The exit panel is rated 5 W and the emergency output is 2 × 5 W + 3 W (13 W in total). In emergency mode the unit delivers 180 minutes of illumination at rated load. Rated IP30, it is intended for dry indoor locations. The exit legend is available in green or red.

The EXIT panel sits between two side-mounted LED heads, so one fitting marks the escape route and lights it at the same time. The internal ledger specifies 2835 SMD LEDs, 12 pieces, in the heads. Charging time is less than 15 hours and the unit operates at 0°C to 50°C. Transfer time is less than 1 second.

At a Glance — Why Buyers Choose the AS-3003

  • Exit sign and emergency light combo: 2-in-1 fitting with a 5 W exit panel plus 2 × 5 W + 3 W (13 W) emergency output.
  • 180 minutes of backup: 3.7 V 2000 mAh Li-ion battery (7.4 Wh), 180 minutes at rated load.
  • Wide-range mains input: AC 85–265 V, 50/60 Hz, covering 120 V and 230 V supplies.
  • 12 × 2835 SMD LEDs: head specification from the internal product ledger.
  • IP30 indoor rating: ABS housing, 465 × 52 × 200 mm, 1.005 kg net weight, 0°C to 50°C operation.
  • Recharge and legend options: charging time less than 15 hours; green or red legend, 10 pcs per carton; OEM and ODM enquiries welcome.

180 Minutes of Emergency Operation

The AS-3003 switches to its 3.7 V 2000 mAh Li-ion battery (7.4 Wh) automatically when the mains supply fails and provides 180 minutes of emergency illumination at rated load. Emergency output is 2 × 5 W + 3 W, 13 W in total. Charging time is less than 15 hours; transfer time is less than 1 second. The battery is covered for 3 years and the rest of the fixture for 5 years.

Exit Panel and Side LED Heads

The 465 × 52 × 200 mm fitting combines a central EXIT panel with two square LED heads mounted on either side. The exit legend is supplied in green or red. The internal ledger specifies 2835 SMD LEDs, 12 pieces, in the heads; the exit panel is rated 5 W. Luminous flux, colour temperature and colour rendering index are not stated on the current catalogue page and are confirmed with our engineering team for your project.

ABS Housing and IP30 Indoor Rating

The body is made of ABS and weighs 1.005 kg net. With an IP30 rating it is intended for dry, indoor environments such as corridors, stairwells, offices and indoor retail areas. It is not intended for humid, dusty, wet or outdoor locations. Operating temperature is 0°C to 50°C; impact resistance (IK) and ingress protection above IP30 are not stated on the current catalogue page.

Built-In Protection and Energy Efficiency

The catalogue records a high-capacity Li-ion battery, all-gold shell construction, energy saving efficiency of up to 88%, short-circuit protection, lightning protection and overload protection. The battery is rated for more than 500 charge and discharge cycles. Charging time is less than 15 hours; detailed charging parameters — charge current and charge voltage — are not published for this model and are confirmed on request.

Wide-Range AC Input

AC 85–265 V, 50/60 Hz input covers low- and high-voltage mains across Europe, the Middle East, South-East Asia, Africa and South America, so distributors can stock one SKU for multiple markets. The same unit operates on 120 V and 230 V supplies without a transformer or converter.

Made to Match Your Brand and Project

OEM and ODM orders are welcome at an MOQ of 100 pcs. Please send your target quantity, destination port and any branding, artwork or packaging requirements so our team can confirm the available options and provide a formal quotation. The catalogue lists an all-gold shell and the ledger lists a neutral colour box; custom colours and non-standard configurations are subject to engineering confirmation.

Where It Works

Suitable for dry indoor interiors: corridors, stairwells, offices, schools, hotels, shopping centres, warehouses and plant rooms. The AS-3003 carries an IP30 rating and is intended for indoor, dry locations only — not for humid, dusty, wet or outdoor environments. The fitting is wall-mounted; fixing accessories can be confirmed with our sales team for your specific installation.

Emergency Lighting Standards and Documentation

Buyers sourcing an exit sign and emergency light combo typically search by product type, battery backup performance, installation scenario and documentation. The AS-3003 is a 2-in-1 combination exit sign with a 3.7 V 2000 mAh Li-ion battery, 12 × 2835 SMD LEDs and 180 minutes of emergency duration. CE and RoHS marks appear on the AS-3003 catalogue page. CE is the applicable standard marked for this model; no EN or IEC standard number is published on the catalogue page, so none is claimed here. Certificate numbers and test reports are confirmed on request.

Order, Packaging and Commercial Terms

Send us your quantity and destination port, and we will confirm the commercial details with the quotation.

  • MOQ: 100 pcs
  • Stock: 10000
  • Lead time: Under 500 pcs: 15 days; 500–5,000 pcs: 30 days; above 5,000 pcs: to be negotiated
  • Payment: To be confirmed at quotation
  • HS code: 9405610000
  • Trade terms: EXW Jiangmen
  • Country of origin: China / Jiangmen
  • Packing: 10 pcs per carton, 56 × 48 × 44 cm, 12.45 kg gross weight; 1.005 kg net per unit
  • Warranty: 5 years (battery 3 years)
  • Customisation: OEM and ODM enquiries welcome

Request a Quote or Samples

Tell us your target quantity and destination port — we will reply within one working day with a quotation, the full specification sheet and sample arrangements. For project tenders, include the intended installation environment and any certification documents you require.

Specifications are subject to change without notice. Source: AS-3003 Product Catalogue and internal product ledger, Jiangmen Anshine Technology Co., Ltd.

Battery & Transport Compliance

Any product containing a lithium cell ships as dangerous goods. These are the fields a freight forwarder will ask for.

ChemistryLi-ion
UN38.3 test summaryAvailable on request
SDS / MSDSAvailable on request

Emergency Lighting Compliance — EN 1838

EN 1838:2013 (Lighting applications — Emergency lighting) defines the minimum lighting requirements for emergency situations within the EU. It covers three functions: ① Escape-route lighting — minimum average 1 lx along the escape path, max-to-min ratio ≤ 10:1; ② Open-area (anti-panic) lighting — minimum average 0.5 lx across the area; ③ High-risk task-area lighting — at least 10% of normal illumination and not less than 15 lx. Our emergency luminaires are designed to meet these illumination levels. The applicable duration (typically 1 h or 3 h) and the notified-body certification for your project are confirmed per model and order — request the declaration of conformity / test report for the exact model you specify.

Questions About This Product

How long does the AS-3003 exit sign and emergency light combo stay lit during a power failure?
The AS-3003 provides 180 minutes of emergency lighting at rated load. A 3.7 V 2000 mAh Li-ion battery (7.4 Wh) powers a 2 × 5 W + 3 W (13 W) output, and the fitting switches to battery power automatically when mains fail. Charging time is less than 15 hours. Transfer time is less than 1 second.
What input voltage does the AS-3003 combination exit sign accept?
The AS-3003 accepts AC 85–265 V at 50/60 Hz. That wide-range input covers both 120 V and 230 V supplies without a transformer or converter, so distributors can stock one SKU for Europe, the Middle East, South-East Asia, Africa and South America. State your market voltage when requesting a quotation.
What battery does the AS-3003 use, and how long does it take to recharge?
The AS-3003 uses a 3.7 V 2000 mAh rechargeable Li-ion battery rated at 7.4 Wh. Recharging takes less than 15 hours. The catalogue records short-circuit protection, lightning protection and overload protection, with energy saving efficiency of up to 88%. The battery is warranted for 3 years and the rest of the fitting for 5 years; charge current and charge voltage are confirmed on request.
Can the AS-3003 be installed outdoors or in damp locations?
No. The AS-3003 is rated IP30 and is intended for dry indoor locations only — corridors, stairwells, offices, schools, hotels and indoor retail. It operates at 0°C to 50°C and is wall-mounted. For humid, dusty, wet or outdoor positions, an IP65 luminaire is required. Fixing accessories and the mounting plan are confirmed with the quotation.
What certifications does the AS-3003 carry?
The AS-3003 carries CE and RoHS marks as shown on its catalogue page. No other certification or standard number is claimed for this model. Certificate numbers and test reports are confirmed on request; for a specific market-access requirement, we provide the technical documentation required to apply for that certificate.
What is the minimum order quantity and lead time for the AS-3003?
The minimum order quantity for the AS-3003 is 100 pcs and trade terms are EXW Jiangmen. Lead time is 15 days under 500 pcs, 30 days for 500–5,000 pcs and to be negotiated above 5,000 pcs. Packing is 10 pcs per carton in a 56 × 48 × 44 cm carton at 12.45 kg gross; net weight is 1.005 kg per unit. HS code is 9405610000.

Ask about AS-3003 Exit Sign and Emergency Light Combo, 180-Minute Backup