AS-E150W / AS-E100W CE-LVD Test Report (FTS25LR-07640S)
Full CE-LVD test report (No. FTS25LR-07640S, issued 23 January 2026, 48 pages) by Guangdong Future Test Services Co., Ltd. for the Anshine LED Emergency Driver, models AS-E150W and AS-E100W. Test specification IEC 61347-2-7:2011+AMD1:2017+AMD2:2021 used in conjunction with IEC 61347-1:2015+AMD1:2017 (TRF-SA61347-2-7-V01); the product fulfils EN 61347-2-7:2012+A1:2019+A2:2022 and EN 61347-1:2015+A1:2021 including EU Group Differences. Model AS-E150W was subjected to the full test programme. Independent type, maintained type, ta 0-45C / tc 70C, Li-ion battery pack 12.8V 21Ah (cell certified to IEC 62133-2), minimum emergency duration 180 minutes. Attachments cover European Group Differences, test switch endurance per IEC 61058-1, independent controlgear requirements per EN IEC 60598-1 and photo documentation.