AS-B001 Aluminum Emergency Exit Sign Light 2 Mounting Options

AS-B001 Aluminum Emergency Exit Sign Light 2 Mounting Options

库存 / Stock:10000

Rated Power
3 W
Emergency Duration
180 min
IP Rating
IP30
Input Voltage
220-240V AC, 50/60Hz
Certifications
CE
Minimum Order Quantity
100 pcs

AS-B001 Aluminum Emergency Exit Sign Light 2 Mounting Options is AS-B001 Emergency Exit Light: Suspended/Wall-Mounted, Maintained Mode, Monthly/Annual Self-Test, Smart MCU Control, Fault Diagnosis, Rapid Switching. Ideal for Offices, Garages, Commercial Spaces.

Lead Timepcs
Under 500 pcs15 days
500 – 5000 pcs30 days
Over 5000 pcsNegotiable

Delivery time is counted after order confirmation and deposit.

Technical Specifications

Technical Specifications
ModelAS-B001Rated Power3 W
Input Voltage220-240V AC, 50/60HzBattery TypeLi-ion
Battery Capacity3.7V 500mAhBattery Energy (Wh)1.85 Wh
Emergency Duration180 minCharging Time15 H
IP RatingIP30Housing MaterialAluminium + ABS + Glass
Impact Resistance GradeIK03MountingSuspended / wall-mounted (single-sided)
Dimensions (mm)360 × 23 × 145 mmNet Weight (kg)0.36 kg
CertificationCEWarranty3 years (battery) / 5 years (other components)
MOQ100 pcsOperating Temperature0°C to 45°C (short-term -5°C to 50°C)
Cycle Life500 cycles or morePacking Size (cm)37.5 × 46 × 32.5 cm (40 pcs/carton)
Package Net Weight (kg)14.5 kgPackage Gross Weight (kg)15.8 kg
Battery ChemistryLi-ion

Trade & Logistics Specifications

Trade TermsEXW
Package Size37.5 × 46 × 32.5 cm (40 pcs/carton)
Gross Weight15.8 kg/carton
HS Code9405610000
Country of OriginChina / Jiangmen

Description

as-b001 led exit sign with arabic and english text, green running man symbol and right arrow for building evacuation

AS-B001 LED Emergency Exit Sign Light — Product Overview

The AS-B001 is a maintained LED emergency exit sign light designed for indoor evacuation routes. Drawing under 3 W from a 220–240 Vac supply, it delivers a standard 180-minute emergency backup from its Li-ion 3.7 V 500 mAh battery. Rated IP30, IK03, and Class I, it is CE and RoHS certified. Measuring 360 × 23 × 145 mm, it features a slim aluminium + ABS + glass housing for discreet installation in offices, garages, and commercial spaces.
Manufactured by Jiangmen Anshine Technology Co., Ltd., the AS-B001 operates in continuous (maintained) mode, charging its battery while illuminating from the mains. Its MCU-based control system ensures precise charging and discharging, automatic fault self-diagnosis, and rapid emergency switching. Built-in programs run monthly and annual self-tests, with an additional manual activation button for on-demand testing. The housing supports both suspended and wall-mounted installations.


At a Glance — Why Buyers Choose the AS-B001

as-b001 led emergency exit sign with aluminum frame, hanging ring and wiring label for commercial ceilings

  • Long-lasting light: 8 pcs DIP 3 mm LEDs rated 3.2 V, providing a full 180-minute emergency runtime.
  • Durable battery: Li-ion 3.7 V 500 mAh pack with excellent thermal stability and ≥500 charge cycles (to 80% capacity); replacement recommended every 3 years.
  • Energy-efficient: 220–240 Vac 50/60 Hz input with a power draw under 3 W (power factor ≥0.5 at 230 Vac), significantly reducing energy consumption.
  • Smart self-maintaining: Automatic monthly and annual self-tests of battery and circuit status, plus a manual test button.
  • Ultra-slim body: Only 23 mm deep and 360 mm long, perfectly discreet for any ceiling or wall.
  • Robust housing: Aluminium + ABS + glass construction, resistant to high temperatures and aging; IP30, IK03, Class I.
  • Certified: Fully CE and RoHS compliant.
  • Flexible and customizable: Customizable light color (white 8500 K / red 625 nm / green 525 nm), panel artwork, and non-standard sizes.
  • B2B ready: MOQ 100 pcs, EXW Jiangmen, 40 pcs per carton, OEM/ODM welcome.


Never Let the Exit Go Dark: 180 Minutes of Backup

The AS-B001 operates in continuous (maintained) mode, illuminating the exit sign from the mains while charging its 3.7 V 500 mAh Li-ion battery. A full charge takes no more than 15 hours at a gentle 100 mA charge current, utilizing a balanced charging algorithm that cuts off at 4.25 V to protect the cells.
When mains power fails, the luminaire automatically switches to emergency mode. It provides a reliable 180-minute emergency runtime, ensuring ample time for safe evacuation without maintenance intervention.


One Sign, Two Installation Options

The housing supports both suspended and wall-mounted installations for maximum flexibility. With its ultra-slim 23 mm profile and a compact 360 × 23 × 145 mm footprint, the AS-B001 sits flush above doorways and along escape routes. A shorter AS-B002 variant (330 × 23 × 145 mm) is available in the same series, and non-standard sizes can be produced on request.


Slim 23 mm Housing, Built for Interiors

Combining an aluminum frame, an ABS housing, and a glass panel, the flame-retardant body is highly resistant to high temperatures and aging. The standard finish is silver, with black and other colors available on request. With an IP30 and IK03 impact rating, it is engineered for reliable long-term use in dry indoor environments.


as-b001 led exit sign side view showing power, trouble, charge indicators and test button

Smart Charging, Self-Diagnosis, and Maintenance

An on-board MCU manages charging and discharging, controlling voltage and current to extend the battery service life to ≥500 cycles.
  • Automatic Tests: Runs a simulated monthly test every 30 days and a full annual test every 52 weeks.
  • Manual Tests: Hold the test button for 4 seconds for a monthly test, or 6 seconds for an annual test (after 24 hours of charge).
  • Status Indicators: Red while charging; Green when fully charged; Slow-flashing green (1 Hz) during monthly test; Fast-flashing green (3 Hz) during annual test; Fast-flashing orange indicates battery replacement is needed.
  • Comprehensive Protection: Includes over-voltage, over-current, over-temperature, short-circuit, and open-circuit protection, plus current limitation.


Efficient by Design, Ready for EU Mains

The AS-B001 draws less than 3 W from a 220–240 Vac 50/60 Hz supply with a power factor of ≥0.5 at 230 Vac (max rated input current 0.02 A). This low-power design significantly cuts energy consumption, making it highly economical for large-scale installations.


Where It Works

Ideal for residential, commercial, and public interiors: shopping malls, hotels, schools, airports, offices, garages, corridors, and stairwells. It operates in a temperature range of 0°C to 45°C (short-term -5°C to 50°C). Note: With an IP30 rating, it is strictly for indoor, dry locations.


Fire-Safety Compliance and Long-Tail Keywords

Designed for fire-safety evacuation routes, the AS-B001 covers essential sourcing terms for buyers, including emergency lighting product terms, battery backup performance, and installation scenarios.
  • Category: LED emergency exit sign light, maintained emergency luminaire.
  • Battery: Standard 180-minute backup.
  • Certification: CE and RoHS.


Order, Packaging, and Commercial Terms

ItemDetail
ItemDetail
MOQ100 pcs
Lead TimeTo be confirmed at quotation
PaymentTo be confirmed at quotation
HS Code9405610000
Packing40 pcs/carton, inner box 148 × 45 × 360 mm
Carton Size & Weight37.5 × 46 × 32.5 cm, N.W 14.5 kg, G.W 15.8 kg
Warranty5 years (3 years on battery pack)
CustomisationLight colour, panel artwork, body colour, non-standard sizes

Request a Quote or Samples

Tell us your target quantity, preferred panel pattern and light colour, and your destination port — we will reply within one working day with a quotation, the full specification sheet and sample arrangements.

Specifications are subject to change without notice. Source: AS-B001 Product Specification, Jiangmen Anshine Technology Co., Ltd.

Battery & Transport Compliance

Any product containing a lithium cell ships as dangerous goods. These are the fields a freight forwarder will ask for.

ChemistryLi-ion
UN38.3 test summaryAvailable on request
SDS / MSDSAvailable on request

Emergency Lighting Compliance — EN 1838

EN 1838:2013 (Lighting applications — Emergency lighting) defines the minimum lighting requirements for emergency situations within the EU. It covers three functions: ① Escape-route lighting — minimum average 1 lx along the escape path, max-to-min ratio ≤ 10:1; ② Open-area (anti-panic) lighting — minimum average 0.5 lx across the area; ③ High-risk task-area lighting — at least 10% of normal illumination and not less than 15 lx. Our emergency luminaires are designed to meet these illumination levels. The applicable duration (typically 1 h or 3 h) and the notified-body certification for your project are confirmed per model and order — request the declaration of conformity / test report for the exact model you specify.

Applications

green as-b001 emergency exit sign with running man icon above a hospital corridor doorway
Hospital
as-b001 led exit sign with running man symbol and left arrow hanging in a bright shopping mall corridor
Shop
Green LED exit sign with running man and arrow mounted in a bus terminal, guiding passengers to the emergency exit
Station
as-b001 led exit sign with running man and arrow mounted above a hotel corridor doorway
Hotel

Questions About This Product

What operating mode and self-test functions does it have?
It is a maintained (continuous) sign: powered by the mains and charged at the same time, switching to battery automatically on outage. The MCU runs a simulated monthly test (about 60 seconds) every 30 days and a 30-minute test every 52 weeks; a test button also forces a manual check (4 s monthly / 6 s annual).
How is the AS-B001 installed?
Suspended or wall-mounted, single-sided display. The body measures 360 × 23 × 145 mm (AS-B002 variant: 330 × 23 × 145 mm), and non-standard sizes can be produced on request.
What battery does it use, and how often is it replaced?
A rechargeable Li-ion 3.7 V 500 mAh pack rated for ≥500 charge cycles. Battery replacement is recommended every 3 years; the orange indicator flashes when the self-test detects battery degradation.
Can the sign be customized?
Yes. Light colour is available in white (8500 K), red (625 nm), green (525 nm) and blue; panel patterns can be selected from our catalog or supplied as your own artwork; body colour and non-standard sizes are available on request. MOQ for custom panel orders is confirmed at quotation.
What are your trade terms and packing details?
MOQ is 100 pcs, trade terms EXW Jiangmen. Packing is 40 pcs per carton (carton 37.5 × 46 × 32.5 cm, N.W 14.5 kg, G.W 15.8 kg). Lead time and payment terms are confirmed at quotation.
How long does the AS-B001 stay lit during a power failure?
Up to 180 minutes of emergency backup. The Li-ion battery fully charges in no more than 15 hours, and the runtime is verified by the built-in monthly and annual self-tests.

Ask about AS-B001 Aluminum Emergency Exit Sign Light 2 Mounting Options

Include quantity and destination and we reply with a specification and quotation.