AS-E303 Emergency Downlight

AS-E303 Emergency Downlight

库存 / Stock:100000

Rated Power
5W
Emergency Duration
180min
IP Rating
IP66
Input Voltage
AC85-265V~50/60Hz
Certifications
LVD, EMC, CE,RoHS
Minimum Order Quantity
100

AS-E303 Emergency Downlight is The AS-E303S/C/R is a dual-function luminaire offering continuous and emergency lighting with self-test modes, suitable for office and corridor installations.

Lead Timepcs
Under 500 pcs7 days
500 – 5000 pcs5 days
Over 5000 pcsNegotiable

Delivery time is counted after order confirmation and deposit.

Technical Specifications

Technical Specifications
ModelAS-E303Rated Power5W
Input VoltageAC85-265V~50/60HzBattery TypeLiFePO₄
Battery Capacity3.2VBattery Energy (Wh)4000mAh
Emergency Duration180minCharging Time< 24 Hrs
Transfer Time≤ 0.5 sIP RatingIP66
Housing MaterialPCImpact Resistance GradeIK07
MountingRecessed / Ceiling Surface-mounted (Recessed mount requires ≥120mm opening; Max. load 1 kg)表面亮度120–600 lm, stepless dimming 20–100%; efficacy ≥100 lm/W
Dimensions (mm)E303R: Φ135×45 (opening Φ120) / E303S: 140×140×45 / E303C: Φ135×45CertificationLVD, EMC, CE,RoHS
Warranty5 years (luminaire) / 3 years (battery pack)MOQ100
Operating Temperature0°C to 45°C (continuous full load); −10°C to 55°C (short-term)Cycle LifeBattery: 500 cycles @80% capacity; LED lifespan ≥50,000 h
Applicable StandardsLVD / EMC / RoHSBattery ChemistryLiFePO₄ (Lithium Iron Phosphate), 3.2V

Trade & Logistics Specifications

Trade TermsEXW
Country of OriginChina

Description

AS-E303 Series — 5W Dual-Function LED Emergency Downlight

The AS-E303S / E303C / E303R is a 2-in-1 luminaire that works as a comfortable everyday downlight — The AS-E303 is a CE-certified LED emergency downlight for the European and export markets, built as a 2-in-1 battery backup downlight: it works as a comfortable everyday ceiling light — and takes over as emergency escape-route lighting the moment the power fails. Its wide AC85–265V input supports global voltage, and the built-in LiFePO₄ battery provides 3 hours of emergency lighting backup.. Powered by a built-in LiFePO₄ battery with 3-hour backup, it combines stepless dimming, 8-level tunable white (2700K–6500K) and 433 MHz wireless control in one compact, IP66-rated fixture. One light for daily lighting, safety and smart control.

Choose Your Mounting Style

Model Form Dimensions Ceiling Opening
AS-E303R Recessed emergency downlight Φ135 × 45 mm Φ120 mm (min.)
AS-E303S Square surface-mounted downlight 140 × 140 × 45 mm —
AS-E303C Round surface-mounted downlight Φ140 × 53 mm —
AS-WRC01 433 MHz remote control (optional) 86 × 40 × 6 mm —
Recessed installation requires a ≥120 mm opening and a ceiling load capacity of 1 kg. Spring clips fit standard ceilings — no special tools needed.

Indicators & Controls at a Glance

LED status indicator

  • Green — mains connected, battery fully charged.
  • Red — charging in progress (turns green when full, approx. 16 h; max. 24 h).
  • Orange — fault alert: rapid flash = battery fault, slow flash = light-source fault.
  • Blue — 433 MHz signal: blinks once every 20 s in standby, once per received command; solid 5 s = sleep mode.

On-fixture test button

  • Long press — increase brightness; long press again to decrease, in a loop.
  • Short press — cycle through the 8 color-temperature levels.
  • 1 s press — simulate a power failure (emergency mode); press twice consecutively in emergency mode to switch it off.
  • 5 s press — start simulated monthly inspection; 8 s press — simulated annual inspection.
  • Double press in standby — activate emergency output.

AS-WRC01 remote

  • Power ON/OFF (mains mode) and Emergency ON/OFF — independently controlled.
  • M / TEST / Y keys — trigger monthly test, power-failure simulation and annual test remotely.
  • Warm / 4000K / Cool keys plus brightness up/down — full lighting tuning from the wall.

Where It Fits

  • Offices & meeting rooms — tunable white for focus and comfort, silent emergency backup.
  • Corridors & stairwells — 125° round lens or 30°×75° wall-beam lens for even escape-route lighting.
  • Hotels & retail — surface-mounted versions need no ceiling cut-out, ideal for retrofits.
  • Damp & semi-outdoor areas — IP66 handles basement passages, covered walkways and utility rooms.
  • Smart homes — 433 MHz control with automatic self-test, no hub required.

Warranty & Maintenance

  • 5-year warranty on the luminaire; 3-year warranty on the battery pack.
  • Battery rated for 500 charge cycles at 80% capacity — replacement recommended every 3 years.
  • Charging: 3.65V / 300 mA (max. 350 mA), with over-charge protection at 3.65 ± 0.01V and over-discharge protection at 2.2 ± 0.1V.
  • Operating range: 0°C–45°C at continuous full load (−10°C–55°C short-term).

Battery & Transport Compliance

Any product containing a lithium cell ships as dangerous goods. These are the fields a freight forwarder will ask for.

ChemistryLiFePO₄ (Lithium Iron Phosphate), 3.2V
UN38.3 test summaryAvailable on request
SDS / MSDSAvailable on request

Emergency Lighting Compliance — EN 1838

EN 1838:2013 (Lighting applications — Emergency lighting) defines the minimum lighting requirements for emergency situations within the EU. It covers three functions: ① Escape-route lighting — minimum average 1 lx along the escape path, max-to-min ratio ≤ 10:1; ② Open-area (anti-panic) lighting — minimum average 0.5 lx across the area; ③ High-risk task-area lighting — at least 10% of normal illumination and not less than 15 lx. Our emergency luminaires are designed to meet these illumination levels. The applicable duration (typically 1 h or 3 h) and the notified-body certification for your project are confirmed per model and order — request the declaration of conformity / test report for the exact model you specify.

Applications

white round ceiling-mounted emergency light installed in a bright residential hallway corridor
Residential apartment corridor
white round ceiling-mounted emergency light with sensor installed in a bright art gallery corridor
Museum
White ceiling-mounted emergency light with dual heads installed in a bright commercial seaside corridor.
Beachfront Hotel
Round surface-mounted emergency downlights on the ceiling of a modern office corridor
Commercial lobby & Lift corridor

Questions About This Product

What is the difference between continuous and non-continuous mode on the AS-E303 emergency downlight?
The AS-E303 offers two operating modes. Continuous mode keeps the luminaire active as a normal light at all times; non-continuous mode runs the emergency function only when needed. The mode is set by your wiring method and can be controlled via the AS-WRC01 433 MHz remote.
How long does the AS-E303 emergency battery last and how long does it take to charge?
The AS-E303 uses a 3.2V LiFePO₄ battery that delivers 3 hours (180 minutes) of 5W emergency lighting with a transfer time of ≤0.5 seconds. A full charge takes about 16 hours from empty (guaranteed within 24 hours); the indicator turns from red to green when charged.
Can one AS-WRC01 remote control multiple AS-E303 lights?
Yes. The AS-WRC01 433 MHz remote controls multiple AS-E303S/C/R luminaires within range: 30 meters in open areas, 15 meters recommended indoors with line of sight. No Wi-Fi or hub is required.
Is the AS-E303 suitable for damp areas and corridors?
Yes. The AS-E303 is rated IP66 — fully dust-tight and protected against water jets — making it suitable for corridors, stairwells, basement passages and covered semi-outdoor areas. Its interchangeable lenses offer a 125° round beam or a 30°×75° rectangular beam for escape routes.
What happens if the AS-E303 battery or LED fails?
The AS-E303 self-reports faults via its LED indicator: rapid orange flashing indicates a battery fault, slow orange flashing indicates a light-source fault. The luminaire carries a 5-year warranty and the battery pack a 3-year warranty (replacement recommended every 3 years, rated 500 cycles at 80% capacity).
Is the AS-E303 suitable for emergency lighting in commercial buildings?
Yes. The AS-E303 is a self-contained emergency downlight with 3-hour LiFePO₄ battery backup, ≤0.5 s transfer time, and built-in monthly/annual self-test simulation for maintenance verification. It is certified to LVD, EMC and RoHS standards. As with all emergency lighting, please confirm the required placement and duration with your local fire and building regulations.

Ask about AS-E303 Emergency Downlight

Include quantity and destination and we reply with a specification and quotation.