AS-B105 LED Emergency Signlight

AS-B105 LED Emergency Signlight

库存 / Stock:100000

Rated Power
3W
Emergency Duration
≥ 180min
IP Rating
IP30 (Indoor use)
Input Voltage
85-265Vac 50/60Hz
Certifications
CE、RoHS、LVD
Minimum Order Quantity
100

AS-B105 LED Emergency Signlight is LED emergency exit sign light AS-B105: 180-min battery backup, auto monthly/annual self-test, CE & RoHS certified. Wall, ceiling & hanging mount.

Lead Timepcs
Under 500 pcs15 days
500 – 5000 pcs30 days
Over 5000 pcsNegotiable

Delivery time is counted after order confirmation and deposit.

Technical Specifications

Technical Specifications
ModelAS-B105Rated Power3W
Input Voltage85-265Vac 50/60HzBattery TypeLi-ion 3.7V
Battery Capacity2400 mAhBattery Energy (Wh)≥9 Wh
Emergency Duration≥ 180minCharging Time≤ 15 hours (MAX)
Transfer Time≤ 2sIP RatingIP30 (Indoor use)
Housing MaterialABS +PCImpact Resistance GradeIK07
Mountinghanging installation, ceiling-mounted installation, and wall-mounted installationSurface luminance50–300 cd/m²
Dimensions (mm)370 X 45 X 230 ( mm )Net Weight (kg)0.53
CertificationCE、RoHS、LVDWarranty5 years (fixture) / 3 years (battery)
MOQ100Operating Temperature0°C to 45°C
Cycle Life≥ 500 cycles (at 0.5C charge/discharge, 25°C, to 80% of initial capacity); Replacement recommended every 3 years.Applicable StandardsEN 1838
Packing Size (cm)52 X 38.5 X 49.5 (cm)(carton, 10pcs)Package Net Weight (kg)10.7 kg
Package Gross Weight (kg)12.5 kgEmergency Switching TestManual Test (Test Button) / Auto-test (Monthly/Annually)
Rated Input Current0.02 A Max.@230VacAbnormal ProtectionOver-voltage, Over-current, Over-temperature, Short-circuit, and Open-circuit protection and Current limitation
Power Factor≥ 0.5 @ 230 VacColor Options (Optional, depending on panel specification)White (8500K) Red ( λd = 625nm) Green ( λd = 525nm )
Operating ModeContinuousBody ColorSilver (Black or other colors available upon request)
ClassificationClass ICharging Voltage4.2V ± 0.1V enter constant current/constant voltage charging; 4.2V cut off charging.
Battery Cycle Life≥ 500 cycles (at 0.5C charge/discharge, 25°C, to 80% of initial capacity); Replacement recommended every 3 years.Extreme Temperature-5°C to 50°C (Short-term Operation)
Light sourceSMD LED

Trade & Logistics Specifications

Trade TermsEXW
Package Size52×38.5×49.5 cm
Gross Weight12.5 kg
HS Code9405610000
Country of OriginChina

Description

AS-B105 LED Emergency Signlight — Reliable Evacuation Indication When It Matters Most

The AS-B105 is a maintained-mode LED emergency exit sign light for indoor corridors, stairways and commercial spaces. It runs on 85–265 Vac, 50/60 Hz with 3 W load power, and its 3.7 V Li-ion battery delivers ≥180 minutes of emergency lighting after a charge time of ≤15 hours. The IP30, Class I, IK07 ABS+PC housing carries CE, RoHS and LVD certification. Installation: hanging, ceiling-mounted or wall-mounted.
Operating in maintained mode, the sign stays illuminated during normal power supply and transfers instantly to its built-in rechargeable battery when the mains fail. The MCU-based control system precisely manages battery charging and discharging, provides fault self-diagnosis, and ensures a fast, reliable emergency transfer.
Built-in power-failure simulation, automatic monthly and annual self-tests, and a manual test button keep the unit verified and audit-ready without extra inspection equipment — ideal for facility managers, contractors and distributors who need dependable, low-maintenance emergency lighting.
Typical applications: residential buildings, offices, hotels, cinemas, shopping malls, schools, garages and indoor corridors.

Indication & Operation Status

  • Charging: red indicator light on
  • Reference photo
  • Fully charged: green indicator light on
  • Simulated emergency / monthly test: green light flashes slowly (1 Hz)
  • Annual test: green light flashes rapidly (3 Hz)
  • Fault: red light flashes quickly
  • Battery degradation detected: orange indicator flashes rapidly to alert maintenance personnel
When mains power fails, the unit automatically switches to emergency mode and supplies power to the load at rated emergency power. When mains power returns, it resumes AC supply and re-enters charging mode automatically.

Self-Test Functions

  • Monthly auto-test: after initial power-on, the device performs its first automatic test in one month, then every 30 days. Each simulated emergency lasts approximately 60 seconds.
  • Annual auto-test: after initial power-on and full charging, the device performs an automatic test every 52 weeks, with automatic low-voltage battery degradation detection.
  • Manual test: press and hold the test button 4 seconds to force a 60-second monthly test; hold 6 seconds to force a 30-minute annual test.

Installation & Maintenance Notes

  • Recommended for indoor use only (IP30).
  • Visually check the indicator light monthly — it should be green and stay on after connection to AC mains.
  • Switch off AC mains monthly for a 30-second discharge test; perform a full discharge annually.
  • Under normal conditions, charge and discharge the battery at least once every six months if the unit is stored unused.
  • Storage: 0 °C to 45 °C, humidity <85%. Avoid mechanical shock, fire, and disassembly of the battery.

Maintenance & Battery Care

  • Visually inspect the indicator monthly (green steady ON when connected to AC mains).
  • Switch off AC mains monthly for a 30-second discharge test; perform a full discharge annually.
  • Charge/discharge the battery once every six months under normal conditions.
  • Disconnect the battery when not in use to prevent over-discharge from circuit-board self-consumption.
  • Storage: 0–35 °C, humidity below 85%. For long-term storage, discharge at least once every six months.
  • Avoid mechanical shock, fire, or attempting to open the battery; keep battery terminals insulated to prevent short circuits.

Packaging & Shipping Information

Model

Qty per Carton

Unit Weight

Inner Box (L×W×H)

Carton (L×W×H)

N.W.

G.W.

AS-B105

20 pcs

0.53 kg

235 × 50 × 375 mm

52 × 38.5 × 49.5 cm

10.7 kg

12.5 kg

Customization / OEM & ODM

  • Custom light color: red, green, blue or white LED options, coordinated with panel process (engraving, printing, film overlay) and printing color.
  • Custom panel pattern: choose from our standard exit-sign pattern library, or send us your requirements for custom colors and patterns.
  • Custom body color: black or other colors available upon request.
Contact us for the full pattern catalog.


Downloads

Battery & Transport Compliance

Any product containing a lithium cell ships as dangerous goods. These are the fields a freight forwarder will ask for.

UN38.3 test summaryAvailable on request
SDS / MSDSAvailable on request

Emergency Lighting Compliance — EN 1838

EN 1838:2013 (Lighting applications — Emergency lighting) defines the minimum lighting requirements for emergency situations within the EU. It covers three functions: ① Escape-route lighting — minimum average 1 lx along the escape path, max-to-min ratio ≤ 10:1; ② Open-area (anti-panic) lighting — minimum average 0.5 lx across the area; ③ High-risk task-area lighting — at least 10% of normal illumination and not less than 15 lx. Our emergency luminaires are designed to meet these illumination levels. The applicable duration (typically 1 h or 3 h) and the notified-body certification for your project are confirmed per model and order — request the declaration of conformity / test report for the exact model you specify.

Applications

Green ceiling-mounted exit sign with directional arrows above a hotel corridor with guests and luggage
Hotel
Ceiling-mounted green exit sign with directional arrows in a hospital corridor, guiding staff and patients to safety.
Hospital
ceiling-mounted green led exit sign with directional arrows above a school corridor walkway
School
Green exit sign with ceiling-mounted emergency light above supermarket checkout aisle guiding shoppers to the door
Shopping mall

Questions About This Product

What is the AS-B105?
The AS-B105 is a maintained-mode LED emergency exit sign light (emergency luminaire) with a built-in rechargeable battery. When mains power fails, it automatically switches to battery power to keep the evacuation sign illuminated for at least 180 minutes.
How long does the battery last during a power failure?
The rated emergency duration is ≥ 180 minutes at full load. Actual runtime depends on battery age and ambient temperature; the rated 180-minute figure is the value used for compliance and specification purposes.
How does the self-test work? Do I need to test it manually?
The unit self-tests automatically — a 60-second monthly test every 30 days and a full annual test every 52 weeks (starting 24 hours after first power-on). Manual testing is also available: hold the test button for 4 seconds to force a monthly test, or 6 seconds to force a 30-minute annual test. No external control panel or software is required.
What do the indicator lights mean?
Red steady = charging; green steady = fully charged; green slow flash (1 Hz) = simulated emergency / monthly test; green fast flash (3 Hz) = annual test; red fast flash = fault; orange fast flash = battery degradation, replacement required.
Can it be installed on a wall, ceiling, or suspended?
Yes. The AS-B105 supports wall-mounted, ceiling-mounted, and hanging (suspended) installation, making it suitable for corridors, stairwells, lobbies, garages, and large open public spaces with different ceiling structures.
Is it suitable for outdoor or wet environments?
No. The AS-B105 is rated IP30 for indoor use only. It is designed for dry indoor areas such as shopping malls, schools, hotels, cinemas, offices, and residential buildings. For damp or outdoor locations, please contact us about higher-IP alternatives.
Can I customize the light color and panel pattern?
Yes. LED colors are available in white (8500 K), red (λd = 625 nm), green (λd = 525 nm), and blue on request, coordinated with panel processing (engraving, printing, film overlay). Custom panel patterns and body colors (silver standard, black or others on request) are also available — send us your artwork or requirements.