Rated Power
9 W
Emergency Duration
180min
IP Rating
IP65
Input Voltage
AC 85–265 V, 50/60 Hz
Certifications
CE,RoHS
Minimum Order Quantity
10pcs

AS-E305 IP65 LED Emergency Bulkhead Light 9W 900lm is The AS-E305 is an IP65-rated LED emergency bulkhead light for commercial and industrial use, offering 900lm at 9W with a 180-minute backup.

Lead Timepcs
Under 500 pcs15 days
500 – 5000 pcs30 days
Over 5000 pcsNegotiable

Delivery time is counted after order confirmation and deposit.

Technical Specifications

Technical Specifications
ModelAS-E305Rated Power9 W
Input VoltageAC 85–265 V, 50/60 HzBattery TypeLiFePO4 3.2 V, 4000 mAh
Battery Capacity3.2VBattery Energy (Wh)4000mAh
Emergency Duration180minCharging Time< 24 h (full charge approx. 16 h)
Transfer Time≤ 0.5 sIP RatingIP65
Housing MaterialABS / PCMountingWall mounted (ceiling mount supported)
Dimensions (mm)L355*W110*H61mmNet Weight (kg)0.47kg
CertificationCE,RoHSWarranty5 years (fixture) / 3 years (battery)
MOQ10pcsOperating Temperature0°C to 55°C
Cycle Life500 cycles @ 80% capacity; Replacement recommended every 3 years.Packing Size (cm)38 x 34 x 48.5 cm
Package Net Weight (kg)9.4 kgPackage Gross Weight (kg)11.7 kg
Battery ChemistryLithium Iron Phosphate (LiFePO4)Conversion Efficiency>90%
Color temperature6000KColor Rendering Index80 ≤ Ra < 90
Over Charge Protection3.65 ± 0.01 V, cut off chargingOver Discharge Protection2.2 ± 0.1 V
OperatingContinuous/Non-continuous mode (selectable via wiring)

Trade & Logistics Specifications

Trade TermsEXW
Package Size38 x 34 x 48.5 cm
Gross Weight11.7 kg
Country of OriginChina

Description

AS-E305 LED Emergency Exit Sign Light — Product Overview

This IP65-rated LED emergency light is a compact, durable solution for emergency lighting in
commercial and industrial environments. Designed for wall or ceiling mounting, it features a rugged,
weatherproof housing and long-lasting LED illumination to ensure safety during power outages.

At a Glance — Why Buyers Choose the AS-E305

  • IP65 Weatherproof — Go Where Indoor Fittings Can't — Dust-tight, water-jet-resistant ABS + PC housing opens up warehouses, car parks, loading bays and covered walkways where ordinary indoor emergency fittings fail, indoors and out.
  • 9 W for 900 lm — Energy Class B — High-efficiency LED and >90% conversion efficiency deliver bright, even emergency light at low running cost, meeting EU energy-efficiency requirements.
  • 180-Minute Backup, 0.5-Second Switchover — A 3.2 V 4000 mAh LiFePO4 battery keeps the fitting lit for 180 minutes and transfers to emergency mode in ≤0.5 s, so there is no dark gap during evacuation.
  • Maintained or Non-Maintained, One Model — Select continuous or non-continuous operation through the wiring method and remote control — one SKU covers both "always-on" corridors and "emergency-only" plant rooms.
  • Self-Test, Fault Reported on the Fitting — Automatic monthly and annual inspections check battery, LED and circuit; orange indicator distinguishes battery fault (rapid flash) from light-source fault (slow flash), so maintenance knows what to replace before inspecting.产品图 / 应急照明灯 / AS-E305 reference photo
  • 3-Year Battery / 5-Year Fitting Warranty — LiFePO4 chemistry rated 500 cycles to 80% capacity, with a 5-year warranty on the luminaire and 3 years on the battery pack.

Short-form bullets

  • IP65 · indoor & outdoor
  • 9 W / 900 lm · Class B
  • 180-min backup · 0.5 s transfer
  • Maintained or non-maintained
  • Auto monthly & annual self-test
  • 5-year fitting warranty

How It Works

Two operating modes — selected by wiring, not by ordering a different model

  • Maintained (continuous) mode — The lamp
  •  stays illuminated whenever AC power is present, and keeps burning on battery when the mains fails. Use this mode for corridors, stairwells and escape routes where the fitting doubles as everyday lighting.
  • Non-maintained (non-continuous) mode — The lamp stays dark during normal operation and lights up only when mains power fails. Use this mode for plant rooms, storage areas and other spaces that are normally unoccupied.
  • The mode is determined by the wiring method and remote control operation, so installers can set the behavior on site — one SKU serves both applications.

Automatic emergency switchover

When mains power fails, the internal circuitry transfers the load to the battery in ≤ 0.5 seconds — faster than the eye can perceive, so there is no visible dark gap in the escape route. After 180 minutes of rated emergency output, the lamp switches off to protect the battery from over-discharge (2.2 V ± 0.1 V cut-off). When AC power returns, the fitting resumes normal operation and the battery begins recharging automatically.

Charging cycle

A fully discharged battery recharges in under 24 hours (typically around 16 hours). The red indicator shows charging in progress and turns green when the battery is full, so site staff can confirm readiness at a glance.

close-up of as-e305 emergency light diffuser showing green status indicator light

LED Indicator Guide

Indicator

Status

Meaning

Green

Steady on

AC power connected; charging completed

Red

Steady on

Battery charging (turns green when full, approx. 16 h)

Orange

Rapid flashing

Battery fault

Orange

Slow flashing

Light source fault

The orange fault codes are deliberately split into battery vs. light-source faults: maintenance staff can tell which spare part to bring before opening the fitting, cutting a typical service visit in half.


Battery & Charging

  • Chemistry: LiFePO4 (lithium iron phosphate), 3.2 V / 4000 mAh (12.8 Wh) — chosen for thermal stability, long cycle life and safety; no cobalt, environmentally friendlier than conventional Li-ion.
  • Cycle life: 500 cycles to 80% of initial capacity — under normal maintained-mode operation this corresponds to roughly 3 years of daily charge/discharge cycling; replacement is recommended every 3 years.
  • Over-charge protection: 3.65 V ± 0.01 V cut-off — charging stops automatically at the safe threshold.
  • Over-discharge protection: 2.2 V ± 0.1 V — the lamp disconnects the battery before deep discharge damage occurs.
  • Storage: if the fitting is stored before installation, keep it between 0 °C and 35 °C, humidity below 85%, and charge/discharge the battery at least once every six months to prevent deep self-discharge.

Installation & Mounting

  • Mounting: wall-mounted as standard (ceiling mounting supported); overall size 355 × 110 × 61 mm.
  • Location: thanks to the IP65 sealed ABS/PC housing, the fitting can be installed in dusty, damp or wash-down environments — warehouses, car parks, loading bays, covered walkways, commercial kitchens — not only in dry indoor spaces.
  • Temperature: rated for 0 °C to 55 °C ambient. Avoid locations outside this range or with continuous immersion in water.
  • Electrical: input AC 85–265 V, 50/60 Hz. Installation and mode selection (maintained / non-maintained) should be carried out by a qualified electrician in accordance with local wiring regulations.

Maintenance & Self-Test

  • Automatic testing — after installation the fitting performs a monthly inspection and an annual inspection automatically; no laptop, control panel or manual routine testing is required.
  • Monthly visual check — confirm the green indicator is steady while AC power is present.
  • Fault reading — orange rapid flash = battery fault; orange slow flash = light-source fault. Replace the indicated part; no further diagnosis needed.
  • Battery — replace every 3 years or when the annual test flags battery degradation. Use only the manufacturer's original battery pack.
  • Cleaning — wipe the diffuser with a soft damp cloth; do not use solvents or high-pressure water jets against the housing seals.


Downloads

Battery & Transport Compliance

Any product containing a lithium cell ships as dangerous goods. These are the fields a freight forwarder will ask for.

ChemistryLithium Iron Phosphate (LiFePO4)
UN38.3 test summaryAvailable on request
SDS / MSDSAvailable on request

Emergency Lighting Compliance — EN 1838

EN 1838:2013 (Lighting applications — Emergency lighting) defines the minimum lighting requirements for emergency situations within the EU. It covers three functions: ① Escape-route lighting — minimum average 1 lx along the escape path, max-to-min ratio ≤ 10:1; ② Open-area (anti-panic) lighting — minimum average 0.5 lx across the area; ③ High-risk task-area lighting — at least 10% of normal illumination and not less than 15 lx. Our emergency luminaires are designed to meet these illumination levels. The applicable duration (typically 1 h or 3 h) and the notified-body certification for your project are confirmed per model and order — request the declaration of conformity / test report for the exact model you specify.

Applications

AS-E305 LED emergency light mounted above a busy subway corridor, illuminated and guiding commuters.
Subway
AS-E305 LED emergency light mounted above a hospital corridor doorway for safe egress during power failure
Hospital
as-e305 led emergency light mounted above a corridor doorway with exit signs and people walking below
Passageway
as-e305 led emergency light mounted above a cafe entrance, illuminating the doorway and seating area
Restaurant

Questions About This Product

What is the AS-E305?
It is an IP65-rated, self-contained LED emergency bulkhead light — a wall/ceiling-mounted luminaire with a built-in LiFePO4 battery that keeps lighting the area for 180 minutes when mains power fails.
What is the difference between maintained and non-maintained mode?
In maintained (continuous) mode the lamp stays on all the time and continues on battery during a power cut. In non-maintained (non-continuous) mode it stays off and only lights up when power fails. The AS-E305 supports both — the mode is selected by the wiring method and remote control, so one model covers both applications.
How long does the battery last in an emergency?
180 minutes at rated load, with a transfer time of ≤0.5 seconds. The 3.2 V 4000 mAh LiFePO4 pack is rated 500 cycles to 80% capacity; replacement is recommended every 3 years.
Is it really suitable for outdoor use?
Yes — IP65 protects against dust ingress and water jets, making it suitable for covered outdoor areas, loading bays, car parks and wash-down zones. It is not intended for continuous immersion.
What temperature range does it work in?
0 °C to 55 °C, which covers most industrial, warehouse and car-park environments. For sub-zero cold-store applications, please contact us.
Can it be customized?
Please contact our sales team regarding branding, packaging and OEM requirements. For MOQ and lead time, request a quotation.

Ask about AS-E305 IP65 LED Emergency Bulkhead Light 9W 900lm

Include quantity and destination and we reply with a specification and quotation.