AS-E306 Emergency Bulkhead Light, Recessed or Wall, Exit Sign

AS-E306 Emergency Bulkhead Light, Recessed or Wall, Exit Sign

库存 / Stock:10000

Rated Power
10 W mains rating + 8 W emergency output
Emergency Duration
180 min
IP Rating
IP65
Input Voltage
AC 85-265 V, 50/60 Hz
Certifications
CE, RoHS
Minimum Order Quantity
100 pcs

AS-E306 Emergency Bulkhead Light, Recessed or Wall, Exit Sign is AS-E306 emergency bulkhead light: 10 W, 8 W output, 180 min backup, AC 85-265 V, IP65, recessed or wall mounted, interchangeable exit sign legend.

Lead Timepcs
Under 500 pcs15 days
500 – 5000 pcs30 days
Over 5000 pcsNegotiable

Delivery time is counted after order confirmation and deposit.

Technical Specifications

Technical Specifications
ModelAS-E306Rated Power10 W mains rating + 8 W emergency output
Input VoltageAC 85-265 V, 50/60 HzBattery TypeLiFePO4
Emergency Duration180 minCharging TimeLess than 15 hours
Transfer TimeLess than 1 secondIP RatingIP65
Housing MaterialFlame-retardant ABSImpact Resistance GradeIK07
MountingRecessed (ceiling) / Wall mountedDimensions (mm)357 x 135 x 65 mm
Net Weight (kg)0.58 kgCertificationCE, RoHS
Warranty5-year fixture, 3-year batteryMOQ100 pcs
Operating Temperature0°C to 50°CCycle LifeMore than 500 cycles
Applicable StandardsCEBattery ChemistryLiFePO4

Trade & Logistics Specifications

Trade TermsEXW
HS Code9405429000
Country of OriginChina / Jiangmen
3-Year Battery Warranty · 5-Year Coverage on Other PartsBacked by a registered manufacturer. See full warranty policy →

Description

AS-E306 Rechargeable Emergency Bulkhead Light - Recessed or Wall Mounted, Interchangeable Exit Sign Legend

The AS-E306 is an LED emergency bulkhead light from Jiangmen Anshine Technology Co., Ltd. One body covers two installation methods - recessed into a ceiling or surface-mounted on a wall - so a single SKU suits both new builds and retrofits. The same housing also works as an exit sign, and its legend graphic can be changed freely, so buyers stock one fitting instead of one per sign design and cut both SKU count and inventory pressure. It provides 180 minutes of emergency lighting from a LiFePO4 3.2 V battery, with a 10 W mains rating and 8 W emergency output. The flame-retardant ABS housing measures 357 x 135 x 65 mm, weighs 0.58 kg net and carries an IP65 rating. Mains input is AC 85-265 V at 50/60 Hz.

At a Glance — Why Buyers Choose the AS-E306

  • 180 minutes of emergency lighting: LiFePO4 3.2 V battery, 8 W emergency output, 180 min runtime at rated load.
  • IP65 housing: flame-retardant ABS, rated for wet, dusty and outdoor positions as well as indoor ones.
  • Two installation methods: recessed ceiling or wall-mounted from the same 357 x 135 x 65 mm body.
  • Wide-range mains input: AC 85-265 V, 50/60 Hz, covering 120 V and 230 V installations without a converter.
  • Also available with an exit sign legend: one fitting marks the escape route and lights it.
  • Protection and warranty: 88% energy saving efficiency, short circuit, lightning and overload protection; 5-year fixture and 3-year battery warranty.

180 minutes of emergency lighting on a single battery

The AS-E306 delivers 180 minutes of emergency lighting at rated load, driven by a LiFePO4 3.2 V battery. Mains input is AC 85-265 V at 50/60 Hz, so one unit covers both 120 V and 230 V installations without a transformer or converter. It draws 10 W on the mains circuit and provides 8 W of emergency output. Transfer to the battery circuit takes less than 1 second, and charging takes less than 15 hours.

IP65 ABS housing for wet, dusty and outdoor positions

The body is flame-retardant ABS with an IP65 rating, which makes this emergency lighting fixture suitable for outdoor, humid and dusty locations as well as indoor ones. The same bulkhead emergency luminaire is offered as a recessed emergency light and as a wall-mounted emergency light, so one model fits both new ceiling cut-outs and surface installations. Operating temperature is 0°C to 50°C and impact resistance is IK07. The catalogue records 88% energy saving efficiency, short circuit protection, lightning protection and automatic overload protection, and the battery is rated for more than 500 charge and discharge cycles.

Sized for corridors, stairwells and car parks

AS-E306 emergency bulkhead light front view with illuminated ribbed diffuser cover, white backgroundEach unit measures 357 x 135 x 65 mm and weighs 0.58 kg net. The same body installs two ways: recessed into a ceiling with spring-loaded mounting clips that grip the cut-out, or surface-mounted flat on a wall from the same housing. Because both methods use one fitting, contractors carry one SKU for new construction and retrofit work instead of two. Fixing accessories, the cut-out and the mounting plan are confirmed with the quotation. The warranty is 5 years for the fixture and 3 years for the battery.

The same body also works as an exit sign

AS-E306 exit sign emergency light showing green EXIT running man legend, white background front viewThe AS-E306 body is also supplied as an exit sign, so one fitting both marks the escape route and lights it. The exit sign legend graphic is interchangeable - the same housing accepts different sign graphics, and the panel can be changed without replacing the whole luminaire. A distributor therefore stocks one light body and changes the legend to suit each project, instead of holding a separate fixture for every arrow or wording variant, which cuts SKU count and ties up less capital in stock. The sign version keeps the 180-minute backup, IP65 rating and both recessed and wall-mounted options. Tell us which legend graphics you need and we will confirm availability with the quotation.

Documentation and order terms

Buyers sourcing emergency lighting typically search by category, backup duration, installation method, ingress protection and documentation. The AS-E306 is a rechargeable emergency bulkhead light with a LiFePO4 3.2 V battery, 8 W emergency output and 180-minute runtime, available as an IP65 recessed or wall-mounted unit and as an exit sign legend version. CE and RoHS are the certifications shown for this model. No EN or IEC standard number is claimed on this page; certificate numbers and test reports are confirmed on request.

Order, Packaging and Commercial Terms

Send us your quantity and destination port, and we will confirm the commercial details with the quotation.

  • MOQ: 100 pcs
  • Stock: 10000
  • Lead time: Under 500 pcs: 15 days; 500-5,000 pcs: 30 days; above 5,000 pcs: to be negotiated
  • Payment: To be confirmed at quotation
  • HS code: 9405429000
  • Trade terms: EXW Jiangmen
  • Country of origin: China / Jiangmen
  • Warranty: 5 years for the fixture, 3 years for the battery
  • Customisation: OEM and ODM enquiries welcome

Request a Quote or Samples

Tell us your target quantity and destination port, and we will reply with a quotation, the full specification sheet and sample arrangements. For project tenders, include the intended installation environment and any certification documents you require.

Specifications are subject to change without notice. Source: AS-E306 product catalogue and internal product ledger, Jiangmen Anshine Technology Co., Ltd.

Battery & Transport Compliance

Any product containing a lithium cell ships as dangerous goods. These are the fields a freight forwarder will ask for.

ChemistryLiFePO4
UN38.3 test summaryAvailable on request
SDS / MSDSAvailable on request

Emergency Lighting Compliance — EN 1838

EN 1838:2013 (Lighting applications — Emergency lighting) defines the minimum lighting requirements for emergency situations within the EU. It covers three functions: ① Escape-route lighting — minimum average 1 lx along the escape path, max-to-min ratio ≤ 10:1; ② Open-area (anti-panic) lighting — minimum average 0.5 lx across the area; ③ High-risk task-area lighting — at least 10% of normal illumination and not less than 15 lx. Our emergency luminaires are designed to meet these illumination levels. The applicable duration (typically 1 h or 3 h) and the notified-body certification for your project are confirmed per model and order — request the declaration of conformity / test report for the exact model you specify.

Applications

Hotel and public building corridors - the AS-E306 provides 180 minutes of emergency lighting and exit marking along escape routes.
Industrial warehouses and workshops - the IP65 ABS housing suits dusty and humid production areas.
Underground car parks and stairwells - recessed installation keeps the 357 x 135 x 65 mm body clear of the walkway.
Retail and shopping centres - a wall-mounted emergency bulkhead light for public and back-of-house areas.

Questions About This Product

How long does the AS-E306 emergency bulkhead light stay lit during a power failure?
180 minutes of emergency lighting at rated load. The AS-E306 runs from a LiFePO4 3.2 V battery and provides 8 W of emergency output, switching to the battery circuit automatically when the mains supply fails. Transfer to emergency mode takes less than 1 second, and a full charge takes less than 15 hours. The battery capacity in mAh is not published for this model and is confirmed with our engineering team if your tender requires it.
What input voltage does the AS-E306 emergency bulkhead light accept?
AC 85-265 V at 50/60 Hz. One unit therefore covers both 120 V and 230 V installations without a transformer or converter. The AS-E306 draws 10 W on the mains circuit. Please state your market voltage when requesting a quotation so that we can confirm the supply configuration and the battery charging arrangement for that market.
What battery does the AS-E306 emergency bulkhead light use?
A LiFePO4 3.2 V battery, with 8 W of emergency output and 180 minutes of runtime at rated load. The catalogue records 88% energy saving efficiency, short circuit protection, lightning protection and automatic overload protection. Charging takes less than 15 hours and transfer to the battery circuit takes less than 1 second. The cell capacity in mAh is not stated on the current catalogue and is confirmed on request.
How is the AS-E306 emergency bulkhead light installed?
One AS-E306 body supports two installation methods - recessed ceiling mounting and wall-mounted fixing - so a single SKU covers both new builds and retrofits. The recessed version is secured by spring-loaded clips that grip the ceiling cut-out, while the wall-mounted version fixes the same housing flat to the wall face. Both use the same 357 x 135 x 65 mm, 0.58 kg IP65 flame-retardant ABS body, which works in dry, humid, dusty and outdoor positions. The cut-out and fixing accessories are confirmed with the quotation and mounting plan.
Can the AS-E306 be used as an exit sign?
Yes. The same AS-E306 body is supplied as an exit sign, so one fitting marks the escape route and lights it, with 180-minute backup from the LiFePO4 3.2 V battery, the same IP65 housing and 8 W emergency output. The legend graphic is interchangeable: the panel can be changed without replacing the luminaire, so you hold one light body and swap the graphic per project instead of stocking a separate fitting for each design. Tell us which legends you need and we will confirm availability with the quotation.
What certifications does the AS-E306 emergency bulkhead light carry?
CE and RoHS are the certifications shown for this model. We do not hold other market-access certificates or listings for it, and no EN or IEC standard number is claimed on this page. Certificate numbers and test reports are confirmed on request, and we can provide the technical documentation required to apply for a specific certificate in your market.
What is the minimum order quantity and lead time for the AS-E306?
MOQ is 100 pcs, trade terms EXW Jiangmen, origin China / Jiangmen, HS code 9405429000. Lead time is 15 days under 500 pcs, 30 days for 500-5,000 pcs and to be negotiated above 5,000 pcs. Stock is 10,000 pcs. The warranty is 5 years for the fixture and 3 years for the battery, and OEM and ODM specifications are welcome.
Can I change the AS-E306 exit sign graphic to reduce stock levels?
Yes. The AS-E306 exit sign uses interchangeable legend graphics, and the panel can be swapped without replacing the whole luminaire. You stock one light body and fit the required graphic - arrow direction, running man or EXIT wording - per project, instead of buying a separate fixture for each variant. That lowers your SKU count, reduces the capital tied up in inventory and simplifies spare-part stocking. The same 357 x 135 x 65 mm IP65 body keeps 180-minute backup and both recessed and wall-mounted installation. Available legend graphics are confirmed with the quotation.

Ask about AS-E306 Emergency Bulkhead Light, Recessed or Wall, Exit Sign