AS-E308 LED Emergency Ceiling Light 18W IP65

AS-E308 LED Emergency Ceiling Light 18W IP65

库存 / Stock:100000

Rated Power
18 W
Emergency Duration
≥180 min
IP Rating
IP65
Input Voltage
AC85-265V 50/60Hz
Certifications
CE / RoHS
Minimum Order Quantity
100

AS-E308 LED Emergency Ceiling Light 18W IP65 is AS-E308 18W LED emergency ceiling light with 1500 lm output, IP65 protection and a LiFePO4 battery delivering 180 minutes backup. CE / RoHS certified for hotels, offices and hospitals.

Lead Timepcs
This model15 working days

Delivery time is counted after order confirmation and deposit.

Technical Specifications

Technical Specifications
ModelAS-E308Rated Power18 W
Input VoltageAC85-265V 50/60HzBattery TypeLiFePO4
Battery Capacity3600 mAhBattery Energy (Wh)23 Wh
Emergency Duration≥180 minCharging Time<24 h (approx. 18 h)
Transfer Time≤1 sIP RatingIP65
Housing MaterialPCImpact Resistance GradeIK07
MountingCeiling-mounted (surface)Dimensions (mm)Φ280 × 65 mm
Net Weight (kg)1.25 kgCertificationCE / RoHS
Warranty5 years (battery 3 years)MOQ100
Operating Temperature0°C to 45°C (short-term -10°C to 55°C)Cycle Life500 cycles @ 80% capacity
Applicable StandardsEN 60598; EN 61347; EN 62471Packing Size (cm)69.5 × 29.5 × 30.5 cm
Package Net Weight (kg)12.5 kg (per carton, 10 pcs)Package Gross Weight (kg)14.8 kg (per carton, 10 pcs)
Battery ChemistryLiFePO4

Trade & Logistics Specifications

Trade TermsEXW
Package Size28.5*28.5*6.8
Gross Weight1.32kg
Country of OriginChina
3-Year Battery Warranty · 5-Year Coverage on Other PartsBacked by a registered manufacturer. See full warranty policy →

Description

The AS-E308 is a 18 W LED emergency ceiling light with a round Φ280 × 65 mm housing, designed for both continuous and emergency illumination in hotels, offices, hospitals, schools and shopping malls. It delivers 1500 lm at 4000 K or 6000 K with a colour rendering index of 80 ≤ Ra < 90. The wide-voltage AC85-265V 50/60 Hz input ( optional) feeds a LiFePO4 6.4 V 3600 mAh battery, and the luminaire switches to battery power within 1 second, sustaining at least 180 minutes of emergency operation. CE and RoHS certified.

AS-E308 IP65 emergency ceiling light resistant to water, moisture and dust

Key Features

  • 18 W LED source with 1500 lm luminous flux, 4000 K / 6000 K CCT options can customize
  • AC85-265V 50/60 Hz wide-voltage input, power factor 65%
  • LiFePO4 6.4 V 3600 mAh battery, ≥ 180 min emergency duration, ≤ 1 s transfer time
  • Maintained / non-maintained operating modes, selectable per project requirement
  • Built-in self-test with automatic monthly and annual inspection
  • IP65 protection rating for dusty, humid and wash-down environments
  • With remote control function for convenient operation
  • Compact Φ280 × 65 mm ceiling-mounted housing, charging time under 24 hours

Durable Construction

The luminaire body is moulded from impact-resistant polycarbonate (PC) with a milky diffuser that spreads light evenly across the room. The sealed construction achieves an IP65 ingress protection rating, keeping out water, moisture and dust, so the fixture stays reliable in corridors, stairwells, washrooms, basements and other demanding interiors. With a conversion efficiency above 90%, most of the stored battery energy is converted into useful emergency light.


AS-E308 ceiling-mounted installation with convenient quick wiring

Intelligent Monitoring

A three-colour indicator and test button on the housing make routine checks simple. The green indicator confirms normal mains power and a full battery, the red indicator illuminates during charging (approximately 18 hours to full), and the orange indicator signals a system fault: rapid flashing for a battery fault, slow flashing for a light source fault. The self-test function performs monthly and annual inspections automatically, and charging is protected at 3.65 ± 0.01 V with over-discharge cut-off at 2.50 ± 0.1 V.

AS-E308 emergency ceiling light for hotels, schools, hospitals and officesEasy Installation

A remote control is included, so you can switch the lamp and trigger tests without a ladder. The AS-E308 mounts directly onto the ceiling with a convenient and quick screw-fix base. The battery cycle life reaches 500 cycles at 80% capacity, with battery pack replacement recommended every 3 years. The luminaire operates continuously from 0°C to 45°C and tolerates short-term extremes from -10°C to 55°C.

AS-E308 charging, power and trouble indicator lights with test button

Applications and Warranty

This emergency ceiling light provides dependable battery backup for public buildings and supports fire-safety compliance in hotels, schools, hospitals, office buildings, shopping malls and residential corridors, keeping escape routes and exit paths illuminated when the mains supply fails. Anshine Technology backs the AS-E308 with a 5-year warranty on the luminaire and a 3-year warranty on the battery pack, subject to the separate warranty card. Cartons pack 10 units with net weight 12.5 kg and gross weight 14.8 kg, carton dimension 69.5 × 29.5 × 30.5 cm.

Downloads

Engineering files

Battery & Transport Compliance

Any product containing a lithium cell ships as dangerous goods. These are the fields a freight forwarder will ask for.

ChemistryLiFePO4
UN38.3 test summaryAvailable on request
SDS / MSDSAvailable on request

Emergency Lighting Compliance — EN 1838

EN 1838:2013 (Lighting applications — Emergency lighting) defines the minimum lighting requirements for emergency situations within the EU. It covers three functions: ① Escape-route lighting — minimum average 1 lx along the escape path, max-to-min ratio ≤ 10:1; ② Open-area (anti-panic) lighting — minimum average 0.5 lx across the area; ③ High-risk task-area lighting — at least 10% of normal illumination and not less than 15 lx. Our emergency luminaires are designed to meet these illumination levels. The applicable duration (typically 1 h or 3 h) and the notified-body certification for your project are confirmed per model and order — request the declaration of conformity / test report for the exact model you specify.

Applications

Hotels, offices, hospitals, schools, shopping malls, corridors, stairwells, basements and other public interiors requiring reliable emergency ceiling lighting.

Questions About This Product

How long does the AS-E308 stay on during a power failure?
The built-in LiFePO4 6.4 V 3600 mAh battery sustains emergency output for at least 180 minutes after a mains failure, with the switchover completed in 1 second or less so the light never appears to go out.
How is the battery charged and maintained?
Charging takes less than 24 hours (approximately 18 hours to full) at a current of 300 mA with a maximum of 350 mA. Over-charge protection cuts off at 3.65 ± 0.01 V and over-discharge protection at 2.50 ± 0.1 V. The battery delivers 500 cycles at 80% capacity and should be replaced every 3 years.
Is the AS-E308 suitable for humid or dusty locations?
Yes. The sealed ceiling-mounted housing carries an IP65 ingress protection rating, resisting water, moisture and dust, which makes it suitable for corridors, stairwells, washrooms, basements and other demanding indoor areas.
Which certifications does the product hold?
The AS-E308 is CE and RoHS certified and complies with the latest safety and EMC standards, tested to EN 60598, EN 61347 and EN 62471.
What is the difference between maintained and non-maintained modes?
In maintained mode the luminaire operates with the mains supply and continues in an emergency; in non-maintained mode it stays off during normal hours and lights up only when the power fails. Both modes are available on the AS-E308 and can be selected according to project requirements.
How does the self-test function work?
The luminaire automatically performs monthly and annual inspections of the battery and light source. A three-colour indicator shows the status: green for normal power and full battery, red while charging, orange for faults (rapid flashing for battery fault, slow flashing for light source fault), and a test button allows manual checks at any time.
Where can the AS-E308 be installed?
It is designed for ceiling-mounted installation in hotels, schools, hospitals, office buildings, shopping malls and residential corridors, providing 1500 lm of even, bright illumination and up to 180 minutes of emergency backup.
Does the AS-E308 come with a remote control?
Yes. The AS-E308 includes a remote control function, so you can switch the luminaire and run emergency tests conveniently without accessing the ceiling-mounted housing directly.

Ask about AS-E308 LED Emergency Ceiling Light 18W IP65