AS-F001 Explosion-Proof LED Exit Sign, Die-Cast Aluminum IP65

AS-F001 Explosion-Proof LED Exit Sign, Die-Cast Aluminum IP65

库存 / Stock:100000

Rated Power
3W @ 230Vac
Emergency Duration
≥180 min
IP Rating
IP65
Input Voltage
AC 85-265 V, 50/60 Hz
Certifications
CE / RoHS
Minimum Order Quantity
100

AS-F001 Explosion-Proof LED Exit Sign, Die-Cast Aluminum IP65 is AS-F001 explosion-proof LED exit sign: 3 W at 230 Vac, 12 pcs DIP 5 mm LEDs, Li-ion 3.7 V battery, 180-min emergency, AC 85-265 V, die-cast aluminum 370 x 70 x 170 mm, IP65, CE / RoHS.

Lead Timepcs
Under 500 pcs15 days
500 – 5000 pcs30 days
Over 5000 pcsNegotiable

Delivery time is counted after order confirmation and deposit.

Technical Specifications

Technical Specifications
ModelAS-F001Rated Power3W @ 230Vac
Input VoltageAC 85-265 V, 50/60 HzBattery TypeLi-ion 3.7 V
Battery Capacity1800 mAhBattery Energy (Wh)6.66 Wh
Emergency Duration≥180 minCharging Time<=15 h
Transfer Time<2sIP RatingIP65
Housing MaterialDie-cast aluminumImpact Resistance GradeIK07
MountingWall-mounted / chain-hung (pendant)Dimensions (mm)370 x 70 x 170 mm (single-sided)
Net Weight (kg)1.75 kgCertificationCE / RoHS
Warranty5 years (battery 3 years)MOQ100
Operating Temperature0 C ~ +45 CCycle Life>=500 cycles
Packing Size (cm)5 pcs/ctn; inner box 370 x 75 x 170 mm; carton 38 x 39 x 20 cm; N.W. 8.8 kg / G.W. 10.5 kgPackage Net Weight (kg)8.6 kg (per carton)
Package Gross Weight (kg)10 kg (per carton)

Trade & Logistics Specifications

Trade TermsEXW
Package Size38 x 39 x 20 cm (carton)
Gross Weight10.5 kg (G.W. per carton)
HS Code9405429000
Country of OriginChina
3-Year Battery Warranty · 5-Year Coverage on Other PartsBacked by a registered manufacturer. See full warranty policy →

Description

AS-F001 Explosion-Proof LED Emergency Exit Sign

The AS-F001 is an explosion-proof LED emergency exit sign for hazardous areas where explosive gases or combustible dust may be present — oil and gas fields, petrochemical and chemical plants, pharmaceutical factories, paint shops, gas stations, mines and tunnels. It runs 12 pcs DIP 5 mm LEDs on 3 W at 230 Vac from AC 85-265 V 50/60 Hz, holds a Li-ion 3.7 V battery with at least 180 minutes of emergency output, and is built into a die-cast aluminum flameproof enclosure rated IP65, Class I and IK07, measuring 370 x 70 x 170 mm and certified CE / RoHS with a 5-year warranty (battery 3 years).

Key Specifications at a Glance

  • Model: AS-F001 single-sided explosion-proof emergency exit sign (AS-F001-2 double-sided: 300 x 75 x 190 mm)
  • Light source: 12 pcs DIP 5 mm LED, long-life type
  • Input power: 3 W at 230 Vac, load power 3 W, rated input current 0.02 A max at 230 Vac
  • Input voltage: AC 85-265 V, 50/60 Hz
  • Battery: Li-ion 3.7 V pack, charge current 200 mA, charging voltage 4.2 V +/- 0.1 V
  • Charge time: 15 hours maximum to full charge
  • Emergency time: at least 180 minutes, cycle life at least 500 cycles
  • Operating mode: continuous (maintained); manual test button and automatic monthly / annual self-test
  • Body: die-cast aluminum flameproof enclosure in silver, corrosion grade WF2, impact-resistant front window
  • Protection: IP65 for indoor use, Class I, IK07 impact rating
  • Operating temperature: 0 C to +45 C (short-term extreme -5 C to 50 C)
  • Dimensions: 370 x 70 x 170 mm, unit weight 1.75 kg
  • Certification: CE / RoHS; warranty 5 years, battery pack 3 years; MOQ 100 pcsAS-F001 die-cast aluminum flameproof housing of the explosion-proof exit sign

Flameproof Die-Cast Aluminum Enclosure

The one-piece die-cast aluminum body is finished in silver epoxy powder coating for corrosion grade WF2, so the sign survives coastal air, chemical plants and wash-down areas. Precision-machined flameproof joints contain any internal explosion inside the enclosure instead of transmitting it to the surrounding atmosphere. The impact-resistant front window is impact and heat resistant and rates IK07, and the whole unit stays dust-tight and jet-water protected at IP65 for indoor industrial use.

Continuous Operation, Self-Test and Status Indicators

The AS-F001 works in continuous (maintained) mode, so the EXIT legend stays lit whenever mains power is on. An MCU-based control board manages charge and discharge, runs fault self-diagnosis and switches to emergency mode automatically within a fraction of a second when the mains fails. Automatic tests run every 30 days for about 60 seconds and every 52 weeks for a full annual discharge after 24 hours of continuous charging; holding the test button for 4 seconds forces a 60-second monthly test, and holding it for 6 seconds forces a 30-minute annual test. Indicators are simple to read: red while charging, green when fully charged, green flashing slowly at 1 Hz in emergency mode, and red flashing quickly on a fault.

AS-F001 DIP 5 mm LED light source behind the green EXIT legend

Efficient DIP LED Optics

Twelve DIP 5 mm LEDs sit behind the engraved EXIT panel, delivering even, glare-free emergency lighting at just 3 W of input power. The LEDs are long-life types, and the light colour can be specified in red, green, blue or white to match the panel process (engraving, printing or film overlay) and printing colour. Over-voltage, over-current, over-temperature, short-circuit and open-circuit protection with current limitation are built in, which keeps the battery and driver safe in unattended installations.

Installation, Packaging and ApplicationsAS-F001 metal outlet port for conduit wiring on the flameproof exit sign

Two mounting options are supported: direct wall mounting, or chain-hung suspension from pipes, trusses and other site structures. A metal outlet port on the side accepts conduit entry so the wiring stays protected by the flameproof enclosure, and the Class I design requires a protective earth connection. Each carton holds 5 pcs, with an inner box of 370 x 75 x 170 mm and a carton of 38 x 39 x 20 cm, net weight 8.8 kg and gross weight 10.5 kg. Typical applications include petrol stations, underground mines, chemical plants, pharmaceutical workshops and grain handling areas.

Downloads

Engineering files

Battery & Transport Compliance

Any product containing a lithium cell ships as dangerous goods. These are the fields a freight forwarder will ask for.

UN38.3 test summaryAvailable on request
SDS / MSDSAvailable on request

Emergency Lighting Compliance — EN 1838

EN 1838:2013 (Lighting applications — Emergency lighting) defines the minimum lighting requirements for emergency situations within the EU. It covers three functions: ① Escape-route lighting — minimum average 1 lx along the escape path, max-to-min ratio ≤ 10:1; ② Open-area (anti-panic) lighting — minimum average 0.5 lx across the area; ③ High-risk task-area lighting — at least 10% of normal illumination and not less than 15 lx. Our emergency luminaires are designed to meet these illumination levels. The applicable duration (typically 1 h or 3 h) and the notified-body certification for your project are confirmed per model and order — request the declaration of conformity / test report for the exact model you specify.

Questions About This Product

Where can the AS-F001 explosion-proof exit sign be installed?
It is built for hazardous areas where explosive gases or combustible dust may be present: oil and gas fields, petrochemical and chemical plants, pharmaceutical factories, paint shops, gas stations, underground mines, tunnels and grain handling areas. The enclosure is rated IP65 for indoor use, Class I for earthing and IK07 for impact, and it operates from 0 C to +45 C (short-term extremes -5 C to 50 C).
How long does the sign stay lit during a power failure?
At least 180 minutes. The Li-ion 3.7 V battery pack is charged at 200 mA with a charging voltage of 4.2 V +/- 0.1 V and reaches full charge in 15 hours maximum; its cycle life is at least 500 cycles at 0.5C and 25 C to 80% of initial capacity, and the battery is covered by a 3-year warranty.
Is it maintained or non-maintained?
It is maintained (continuous) operation: the EXIT legend stays lit all the time while mains power is present, and the unit switches automatically to battery-powered emergency mode when the mains fails. Power returns, the driver resumes AC supply and the battery starts charging again.
How do the self-test and the indicator lights work?
The MCU runs a monthly test of about 60 seconds every 30 days and a full annual discharge test every 52 weeks after 24 hours of continuous charging. Holding the test button for 4 seconds forces a 60-second monthly test; holding it for 6 seconds forces a 30-minute annual test. Indicators show red while charging, green when fully charged, green flashing slowly at 1 Hz in emergency mode, and red flashing quickly when a fault is detected.
What are the electrical ratings and built-in protections?
Input voltage is AC 85-265V 50/60Hz, input power 3 W at 230 Vac, load power 3 W and rated input current 0.02 A maximum at 230 Vac. The driver includes over-voltage, over-current, over-temperature, short-circuit and open-circuit protection with current limitation, and the electrical classification is Class I, so a protective earth connection is required.
What is the difference between AS-F001 and AS-F001-2?
AS-F001 is the single-sided version measuring 370 x 70 x 170 mm, viewed from one direction, which suits corridors and passages. AS-F001-2 is the double-sided version measuring 300 x 75 x 190 mm, visible from two directions at once, which suits intersections, halls and cross-passages. Both support wall mounting or chain-hung suspension from pipes and trusses.
What are the MOQ, certification, warranty and packing details?
MOQ is 100 pcs. The sign is CE / RoHS certified. Warranty is 5 years for the unit with a 3-year warranty on the battery pack. Packing is 5 pcs per carton, inner box 370 x 75 x 170 mm, carton 38 x 39 x 20 cm, net weight 8.8 kg and gross weight 10.5 kg.

Ask about AS-F001 Explosion-Proof LED Exit Sign, Die-Cast Aluminum IP65

Include quantity and destination and we reply with a specification and quotation.